Higole 21.5" All-in-One PC N100 8GB 128GB
- All-in-One PC
- All-in-One
Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.
DELL
2U rack server with dual 20-core Xeon 6148 CPUs, 512GB DDR4 memory and 64TB of 3.5-inch 7.2K RPM SAS storage on a PERC H730 RAID controller
The Dell PowerEdge R740 2U rack server targets organisations that run dense software-defined storage, traditional applications, virtualisation, private cloud or high-performance computing workloads. Dual Xeon Gold 6148 processors and 512 GB of DDR4 memory deliver the compute headroom those tasks demand. Redundant hot-swappable power supplies keep critical services online during maintenance.
A factory-supplied rail kit lets the chassis slide into standard racks without extra hardware sourcing. Windows Server 2022 Standard 64-bit with a 16-core licence is included, removing a separate procurement step for the hypervisor or application host layer. The PERC H730 12 Gb/s RAID controller with 2 GB non-volatile cache and the Broadcom BCM5720 quad-port 1 GbE controller are also integrated, so storage and networking are operational once drives are seated.
The array ships as 64 TB raw (8 × 8 TB) of 3.5-inch enterprise nearline SAS spinning at 7.2 K rpm on a 12 Gb/s bus. That drive count and interface define the maximum addressable storage before any expansion shelf is added. Buyers who need more raw capacity or all-flash performance will need a different chassis or external enclosure.
Za ovaj artikl još nisu objavljene specifikacije.
The PERC H730 RAID controller is a field-replaceable module; if the 2GB NV cache fails, the card can be swapped without removing the server from the rack.
Thermal limits of the 2U chassis and the redundant power supply capacity will cap sustained turbo before the CPUs reach their maximum frequency.
The redundant power supplies share the load, so each unit typically runs at partial capacity, reducing heat and fan noise during continuous operation.
Također u ovoj kategoriji
Ista polica, ista blagajna — osam valuta i blokada tečaja na 30 minuta.
Ono što šaljete, i ono u čemu gledate cijene.
Poslano iz Vašeg novčanika na blagajni
Samo prikaz — katalog je izražen u dolarima
Nijedna valuta ne odgovara.
Odaberite jezik na kojem Vam se stranica obraća.
Nema odgovarajućeg jezika.
Novi ste ovdje?
Već imate račun?
Ne postoji automatsko resetiranje: ova trgovina ne šalje e-poštu, stoga ne postoji jednokratna poveznica koju biste mogli zatražiti. Ostavite adresu uz svoj račun, netko će je ručno obraditi.
Zahtjev zaprimljen
Ništa neće stići u Vaš pretinac e-pošte — ova trgovina uopće ne šalje e-poštu. Netko će to ručno preuzeti.
Sjetili ste se?