Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.

Praćeni artikli Prijava

MINUTEMAN

MINUTEMAN ED3000RTXL2U 3000VA 2700W UPS 2U Tower/Rack/Wall Mountable

SKU CH-J2MF-YFK8F MPN ED3000RTXL2U

Online double-conversion UPS delivering 3000 VA and 2700 W with eight outlets in a 2U rack/tower chassis

  • International Version120V
  • Input Voltage Range0-160VAC
  • Input Frequency50/60Hz +/- 6Hz Auto-sensing
  • Input ConnectionNEMA L5-30P
  • VA Rating3000VA
  • Watts2700W

Precrtane verzije postoje, ali nisu dostupne ovdje.

  • True on-line double-conversion protects critical loads with clean 120 V output
  • 9 power factor delivers 2700 W real power from 3000 VA rating
  • Flexible 2U rack tower or wall mounting fits high-density installations
  • Eight outlets including NEMA L5-30R and seven 5-15/20R support diverse equipment
  • Hot-swappable BM0032 battery module enables replacement without downtime

3000VA Double-Conversion UPS for Rack

The Minuteman Endeavor ED3000RTXL2U is a true on-line double-conversion UPS rated at 3000VA and 2700W with a 0.9 output power factor. It accepts 120V input via a NEMA L5-30P connection and delivers user-selectable 120V or 110V output through eight receptacles, including one NEMA L5-30R and seven NEMA 5-15/20R outlets. The unit fits a 2U rack space and includes attached rackmount ears for high-density deployments.

Suited for Critical Servers Needing Pure Sine-Wave

IT managers protecting mission-critical servers, networking gear or storage arrays benefit from continuous power conditioning and zero transfer time during outages. The three controllable load banks allow sequenced shutdowns or selective shedding of non-essential loads. Buyers who need extended runtime beyond 12 minutes at half load or 3.5 minutes at full load should consider external battery packs or a higher-capacity UPS platform.

Sustained Load Performance Within Thermal Limits

Under continuous full load the sealed lead-acid batteries provide 3.5 minutes of backup before depletion, while half-load conditions extend runtime to 12 minutes. Recharging to 90 percent capacity requires approximately 8 hours from total discharge. The unit operates reliably between 32 and 104°F and meets cTUVus, FCC Class A, CE, Energy Star and RoHS2 approvals for regulated environments.

Istaknuto

  • True on-line double-conversion protects critical loads with clean 120 V output
  • 9 power factor delivers 2700 W real power from 3000 VA rating
  • Flexible 2U rack tower or wall mounting fits high-density installations
  • Eight outlets including NEMA L5-30R and seven 5-15/20R support diverse equipment
  • Hot-swappable BM0032 battery module enables replacement without downtime

Specifikacije

BrandMINUTEMAN
SeriesENDEAVOR
ModelED3000RTXL2U
International Version120V
Input Voltage Range0-160VAC
Input Frequency50/60Hz +/- 6Hz Auto-sensing
Input ConnectionNEMA L5-30P
VA Rating3000VA
Watts2700W
Output Voltage120VAC, User selectable: 110VAC
Output Frequency50/60Hz +/- 0.5Hz unless synchronized to line
Outlets8
Outlet Type[7] 5-15/20R & [1] L5-30R
Battery TypeSealed Lead Acid
Battery Run TimeHalf Load: 12 min
Full Load: 3.5 min
Battery Recharge Time8 hours to 90% from total discharge
Battery ReplaceableBM0032
ApprovalscTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class B (1K & 1.5K), FCC Class A (2K & 3K), CE certified, Energy Star certified, RoHS2 (EU Directive 2011/65/EU)
Surge Energy Rating1000 Joules
TemperatureOperating Temperature: +32 to +104°F (0 to 40°C)
Storage Temperature: +5 to +113°F (-15 to +45°C)
Humidity95% non-condensing
Dimensions3.5" x 19" x 24.5"
Weight70.5 lbs.
Težina pošiljke41.28 kg
Dimenzije pakiranja998 × 599 × 216 mm

Druge verzije ovog modela

još 5 u istoj seriji

Ista obitelj, različita memorija, hladnjak ili frekvencija — usporedite prije kupnje.

Pitanja o ovom artiklu

Do I need a NEMA L5-30P wall receptacle to plug in the ED3000RTXL2U?

Yes, the UPS input connection is a NEMA L5-30P plug rated for 120 V, so a matching 30 A receptacle on a dedicated circuit is required before installation.

Can the 5-15/20R outlets power older servers that only accept 110 VAC?

The output voltage is user-selectable between 120 VAC and 110 VAC, allowing the seven 5-15/20R receptacles to match legacy equipment that expects 110 V.

How do I verify the UPS is delivering clean power after setup?

The front LCD shows real-time output voltage and frequency (50/60 Hz ±0.5 Hz), load percentage, and battery status so you can confirm the 0.9 power-factor output is within spec.

Također u ovoj kategoriji

Kupci su usporedili ovo

Ista polica, ista blagajna — osam valuta i blokada tečaja na 30 minuta.