MINUTEMAN
MINUTEMAN ED3000RTXL2U 3000VA 2700W UPS 2U Tower/Rack/Wall Mountable
Online double-conversion UPS delivering 3000 VA and 2700 W with eight outlets in a 2U rack/tower chassis
- International Version120V
- Input Voltage Range0-160VAC
- Input Frequency50/60Hz +/- 6Hz Auto-sensing
- Input ConnectionNEMA L5-30P
- VA Rating3000VA
- Watts2700W
Model ED3000RTXL2U
- ED3000RTXL2U
- ED1000RTXL2U
- ED1000RTXL2UNC
- ED10KRT
- ED10KRT-10KTF2
- ED10KRT-3KTF
- ED10KRT-5KTF
- ED10KRT-6KTF2
- ED10KRT-8KTF2
- ED10KTF
- ED2000RTXL2U
- ED2000RTXL2UNC
Pokaż jeszcze 16 konfiguracji
- ED3000RTXL2UNC
- ED-3KTF
- ED5KRT
- ED5KRT-3KTF
- ED5KRT-5KTF
- ED-5KTF
- ED6KRT
- ED6KRT-3KTF
- ED6KRT-5KTF
- ED6KRT-6KTF2
- ED6KTF
- ED8KRT
- ED8KRT-3KTF
- ED8KRT-5KTF
- ED8KRT-6KTF2
- ED8KRT-8KTF2
Przekreślone wersje istnieją, ale nie są dostępne w tym miejscu.
- True on-line double-conversion protects critical loads with clean 120 V output
- 9 power factor delivers 2700 W real power from 3000 VA rating
- Flexible 2U rack tower or wall mounting fits high-density installations
- Eight outlets including NEMA L5-30R and seven 5-15/20R support diverse equipment
- Hot-swappable BM0032 battery module enables replacement without downtime
3000VA Double-Conversion UPS for Rack
The Minuteman Endeavor ED3000RTXL2U is a true on-line double-conversion UPS rated at 3000VA and 2700W with a 0.9 output power factor. It accepts 120V input via a NEMA L5-30P connection and delivers user-selectable 120V or 110V output through eight receptacles, including one NEMA L5-30R and seven NEMA 5-15/20R outlets. The unit fits a 2U rack space and includes attached rackmount ears for high-density deployments.
Suited for Critical Servers Needing Pure Sine-Wave
IT managers protecting mission-critical servers, networking gear or storage arrays benefit from continuous power conditioning and zero transfer time during outages. The three controllable load banks allow sequenced shutdowns or selective shedding of non-essential loads. Buyers who need extended runtime beyond 12 minutes at half load or 3.5 minutes at full load should consider external battery packs or a higher-capacity UPS platform.
Sustained Load Performance Within Thermal Limits
Under continuous full load the sealed lead-acid batteries provide 3.5 minutes of backup before depletion, while half-load conditions extend runtime to 12 minutes. Recharging to 90 percent capacity requires approximately 8 hours from total discharge. The unit operates reliably between 32 and 104°F and meets cTUVus, FCC Class A, CE, Energy Star and RoHS2 approvals for regulated environments.
Najważniejsze cechy
- True on-line double-conversion protects critical loads with clean 120 V output
- 9 power factor delivers 2700 W real power from 3000 VA rating
- Flexible 2U rack tower or wall mounting fits high-density installations
- Eight outlets including NEMA L5-30R and seven 5-15/20R support diverse equipment
- Hot-swappable BM0032 battery module enables replacement without downtime
Specyfikacja
| Brand | MINUTEMAN |
|---|---|
| Series | ENDEAVOR |
| Model | ED3000RTXL2U |
| International Version | 120V |
| Input Voltage Range | 0-160VAC |
| Input Frequency | 50/60Hz +/- 6Hz Auto-sensing |
| Input Connection | NEMA L5-30P |
| VA Rating | 3000VA |
| Watts | 2700W |
| Output Voltage | 120VAC, User selectable: 110VAC |
| Output Frequency | 50/60Hz +/- 0.5Hz unless synchronized to line |
| Outlets | 8 |
| Outlet Type | [7] 5-15/20R & [1] L5-30R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Half Load: 12 min Full Load: 3.5 min |
| Battery Recharge Time | 8 hours to 90% from total discharge |
| Battery Replaceable | BM0032 |
| Approvals | cTUVus (Conforms to UL1778 5th Edition & CSA 22.2 no. 107.3-14 / R: 2014), FCC Class B (1K & 1.5K), FCC Class A (2K & 3K), CE certified, Energy Star certified, RoHS2 (EU Directive 2011/65/EU) |
| Surge Energy Rating | 1000 Joules |
| Temperature | Operating Temperature: +32 to +104°F (0 to 40°C) Storage Temperature: +5 to +113°F (-15 to +45°C) |
| Humidity | 95% non-condensing |
| Dimensions | 3.5" x 19" x 24.5" |
| Weight | 70.5 lbs. |
| Waga przesyłki | 41.28 kg |
| Wymiary opakowania | 998 × 599 × 216 mm |
Inne wersje tego modelu
Jeszcze 5 w tej samej serii
Ta sama rodzina, inna pamięć, inne chłodzenie lub taktowanie — proszę porównać przed decyzją.
MINUTEMAN ED2000RTXL2U 2000VA 1800W 120V 2U UPS
- 120V
- 0-160VAC
MINUTEMAN ED5KRT UPS 5000VA 4500W 4U Rack/Tower
- 208 (Default), 220,…
- 156-280VAC
Pytania dotyczące tego produktu
Do I need a NEMA L5-30P wall receptacle to plug in the ED3000RTXL2U?
Yes, the UPS input connection is a NEMA L5-30P plug rated for 120 V, so a matching 30 A receptacle on a dedicated circuit is required before installation.
Can the 5-15/20R outlets power older servers that only accept 110 VAC?
The output voltage is user-selectable between 120 VAC and 110 VAC, allowing the seven 5-15/20R receptacles to match legacy equipment that expects 110 V.
How do I verify the UPS is delivering clean power after setup?
The front LCD shows real-time output voltage and frequency (50/60 Hz ±0.5 Hz), load percentage, and battery status so you can confirm the 0.9 power-factor output is within spec.
Także w tym dziale
Klienci porównywali też te produkty
Ten sam dział, ta sama kasa — osiem kryptowalut i 30-minutowa blokada kursu.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case
DOCTOR METAL 120 mm case fan 3-pack with controller
- Case Fan
- Case