NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.
myVolts
Delivers 450 W at 12 V with 37.5 A output, built-in remote sense, forced-air cooling and full protection suite for LED lighting and industrial control systems
The myVolts SE-450 delivers a steady 12 V at 37.5 A for LED lighting, light boxes, strip installations and industrial control cabinets. It is built for integrators who need a single-output unit that fits standard AT mounting and includes a remote-sense function for voltage accuracy at the load.
Forced air cooling comes from a built-in DC ball-bearing fan that runs whenever the unit is powered. Protections against short circuit, overload, over voltage and over temperature activate automatically, keeping the enclosure within safe limits during typical lighting or monitoring duty.
The supply maintains its rated 450 W output continuously thanks to the active cooling design and surge-current limiting at the AC input. Remote sensing compensates for cable drop so the load sees the correct voltage even during extended operation in automation, laser or distribution-cabinet systems.
| Type | AT |
|---|
Mount the unit with clearance for the built-in DC ball bearing fan airflow, connect the AC input after confirming the voltage selector switch position, then wire the 12 V output terminals; the step most often missed is attaching the remote sense leads to the load so voltage drop under 37.5 A is compensated.
The internal DC ball bearing fan is the only moving part; plan to clean dust from its intake vents periodically and replace the fan assembly if bearing noise appears or airflow drops enough to trigger over-temperature protection.
Forced air cooling by the built-in fan sets the practical ceiling; sustained 450 W output at 12 V 37.5 A will hit over-temperature protection first if inlet air exceeds the unit's rated ambient or if dust restricts the fan.
Također u ovoj kategoriji
Ista polica, ista blagajna — osam valuta i blokada tečaja na 30 minuta.
Ono što šaljete, i ono u čemu gledate cijene.
Poslano iz Vašeg novčanika na blagajni
Samo prikaz — katalog je izražen u dolarima
Nijedna valuta ne odgovara.
Odaberite jezik na kojem Vam se stranica obraća.
Novi ste ovdje?
Već imate račun?
Ne postoji automatsko resetiranje: ova trgovina ne šalje e-poštu, stoga ne postoji jednokratna poveznica koju biste mogli zatražiti. Ostavite adresu uz svoj račun, netko će je ručno obraditi.
Zahtjev zaprimljen
Ništa neće stići u Vaš pretinac e-pošte — ova trgovina uopće ne šalje e-poštu. Netko će to ručno preuzeti.
Sjetili ste se?