NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
myVolts
Delivers 450 W at 12 V with 37.5 A output, built-in remote sense, forced-air cooling and full protection suite for LED lighting and industrial control systems
The myVolts SE-450 delivers a steady 12 V at 37.5 A for LED lighting, light boxes, strip installations and industrial control cabinets. It is built for integrators who need a single-output unit that fits standard AT mounting and includes a remote-sense function for voltage accuracy at the load.
Forced air cooling comes from a built-in DC ball-bearing fan that runs whenever the unit is powered. Protections against short circuit, overload, over voltage and over temperature activate automatically, keeping the enclosure within safe limits during typical lighting or monitoring duty.
The supply maintains its rated 450 W output continuously thanks to the active cooling design and surge-current limiting at the AC input. Remote sensing compensates for cable drop so the load sees the correct voltage even during extended operation in automation, laser or distribution-cabinet systems.
| Type | AT |
|---|
Mount the unit with clearance for the built-in DC ball bearing fan airflow, connect the AC input after confirming the voltage selector switch position, then wire the 12 V output terminals; the step most often missed is attaching the remote sense leads to the load so voltage drop under 37.5 A is compensated.
The internal DC ball bearing fan is the only moving part; plan to clean dust from its intake vents periodically and replace the fan assembly if bearing noise appears or airflow drops enough to trigger over-temperature protection.
Forced air cooling by the built-in fan sets the practical ceiling; sustained 450 W output at 12 V 37.5 A will hit over-temperature protection first if inlet air exceeds the unit's rated ambient or if dust restricts the fan.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?