Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

APC

APC APDU11450ME NetShelter Metered 3-Phase PDU 42-Outlet 34.6kW 415V 60A

SKU CH-E25V-RNM5Q MPN APDU11450ME

A metered three-phase PDU delivering 34.6 kW at 415 V with 42 IEC outlets and a 60 A IEC 60309 plug

  • TypePDUs & Line Conditioners
  • Rack Size0U
  • Metered input monitoring tracks real-time power draw
  • 42 outlets supply dense rack deployments
  • 6 kW three-phase capacity handles heavy loads
  • 21 C13/C15 and 21 C13/C15/C19/C21 receptacles fit mixed gear
  • 84 ft cord with IEC 60309 60 A plug reaches distant feeds

Metered 3-phase power distribution

This metered power distribution unit delivers 34.6 kW at 415 V three-phase for high-density rack environments. It mounts in a 0U vertical form factor and provides 42 IEC 60320 outlets split between C13/C15 and C13/C15/C19/C21 combinations. A 9.84 ft cord with IEC 60309 60 A 3P+N+PE plug connects to the supply, while an RJ-45 network port enables remote current monitoring.

Suitable for three-phase metered loads

Data-centre operators who need per-phase current visibility across 42 outlets will find the metering and network interface match their requirements. The unit is not for single-phase installations, for sites that require only basic unmetered distribution, or for cabinets that cannot accommodate a 0U vertical mounting profile.

34.6 kW three-phase 415 V 60 A rating

The 34.6 kW capacity at 415 V with a 60 A three-phase input determines whether the PDU matches the available supply and the total connected load. If the facility provides 400 V 63 A service instead, the alternative 43.5 kW rating applies, but the 415 V 60 A figure is the decisive specification for this deployment.

Helstu kostir

  • Metered input monitoring tracks real-time power draw
  • 42 outlets supply dense rack deployments
  • 6 kW three-phase capacity handles heavy loads
  • 21 C13/C15 and 21 C13/C15/C19/C21 receptacles fit mixed gear
  • 84 ft cord with IEC 60309 60 A plug reaches distant feeds

Tæknilýsing

BrandAPC
ModelAPDU11450ME
Part NumberAPDU11450ME
TypePDUs & Line Conditioners
Rack Size0U
Sendingarþyngd16.78 kg
Stærð sendingar2083 × 254 × 127 mm

Spurningar um þessa vöru

What does the 34.6 kW rating mean for my rack installation?

At 415 V three-phase the unit delivers up to 34.6 kW, giving you 60 A per phase to power dense server loads across all 42 outlets.

How does the IEC 60309 60 A 3P+N+PE inlet limit what I can connect?

The 60 A three-phase inlet caps total draw at 60 A per phase, so the PDU cannot exceed 34.6 kW at 415 V even if individual outlets could take more.

What rack space and mounting does the 0U vertical design need?

The 0U vertical form factor mounts in the side channel of a standard 42 U rack without consuming any horizontal U space.

Einnig í þessum vöruflokki

Fólk bar þetta saman

Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.