APC APDU11450ME NetShelter Metered 3-Phase PDU 42-Outlet 34.6kW 415V 60A
A metered three-phase PDU delivering 34.6 kW at 415 V with 42 IEC outlets and a 60 A IEC 60309 plug
- TypePDUs & Line Conditioners
- Rack Size0U
- Metered input monitoring tracks real-time power draw
- 42 outlets supply dense rack deployments
- 6 kW three-phase capacity handles heavy loads
- 21 C13/C15 and 21 C13/C15/C19/C21 receptacles fit mixed gear
- 84 ft cord with IEC 60309 60 A plug reaches distant feeds
Metered 3-phase power distribution
This metered power distribution unit delivers 34.6 kW at 415 V three-phase for high-density rack environments. It mounts in a 0U vertical form factor and provides 42 IEC 60320 outlets split between C13/C15 and C13/C15/C19/C21 combinations. A 9.84 ft cord with IEC 60309 60 A 3P+N+PE plug connects to the supply, while an RJ-45 network port enables remote current monitoring.
Suitable for three-phase metered loads
Data-centre operators who need per-phase current visibility across 42 outlets will find the metering and network interface match their requirements. The unit is not for single-phase installations, for sites that require only basic unmetered distribution, or for cabinets that cannot accommodate a 0U vertical mounting profile.
34.6 kW three-phase 415 V 60 A rating
The 34.6 kW capacity at 415 V with a 60 A three-phase input determines whether the PDU matches the available supply and the total connected load. If the facility provides 400 V 63 A service instead, the alternative 43.5 kW rating applies, but the 415 V 60 A figure is the decisive specification for this deployment.
Акценти
- Metered input monitoring tracks real-time power draw
- 42 outlets supply dense rack deployments
- 6 kW three-phase capacity handles heavy loads
- 21 C13/C15 and 21 C13/C15/C19/C21 receptacles fit mixed gear
- 84 ft cord with IEC 60309 60 A plug reaches distant feeds
Спецификации
| Brand | APC |
|---|---|
| Model | APDU11450ME |
| Part Number | APDU11450ME |
| Type | PDUs & Line Conditioners |
| Rack Size | 0U |
| Тегло на пратката | 16.78 kg |
| Размери на опаковката | 2083 × 254 × 127 mm |
Въпроси за този артикул
What does the 34.6 kW rating mean for my rack installation?
At 415 V three-phase the unit delivers up to 34.6 kW, giving you 60 A per phase to power dense server loads across all 42 outlets.
How does the IEC 60309 60 A 3P+N+PE inlet limit what I can connect?
The 60 A three-phase inlet caps total draw at 60 A per phase, so the PDU cannot exceed 34.6 kW at 415 V even if individual outlets could take more.
What rack space and mounting does the 0U vertical design need?
The 0U vertical form factor mounts in the side channel of a standard 42 U rack without consuming any horizontal U space.