Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.

Vaktaðar vörur Skrá inn

Tripp Lite

Tripp Lite SU3000XLCD 3000VA 2700W 120V Double-Conversion UPS

SKU CH-TKZB-3M8ZT MPN SU3000XLCD

Double-conversion UPS delivers 120 V sine-wave output with zero transfer time, 1770 W capacity, seven NEMA outlets and user-replaceable batteries

  • International Version120V
  • Input ConnectionNEMA 5-20P
  • VA Rating1960 VA
  • Watts1770 Watts
  • Output Voltage120V
  • Output Frequency50 / 60 Hz
  • Double-conversion topology delivers clean sine-wave power with zero transfer time
  • 4 minutes runtime at full 1770 W load protects critical workloads
  • User-replaceable VRLA batteries extend service life without technician visits
  • LCD interface shows real-time UPS status and site-power data at a glance
  • USB, RS-232, contact closure and optional SNMP card enable automated shutdowns

SmartOnline Double-Conversion UPS

The Tripp Lite SU3000XLCD is a 3000VA double-conversion uninterruptible power supply designed for critical server and network equipment. It continuously converts incoming AC to DC and back to AC, delivering regulated 120V sine-wave output with zero transfer time during outages. This topology protects connected hardware from brownouts, overvoltages and line noise without draining the battery.

Tower Chassis with NEMA Outlets and Management Slots

The tower unit measures 13.63" x 8.43" x 16.23" and weighs 73.42 lbs. It provides six NEMA 5-20R receptacles and one NEMA L5-20R receptacle for secure locking connections. A front-panel LCD reports operating mode and detailed power data at a glance. Rear interfaces include USB, RS-232, contact-closure and an open slot for an optional SNMP network management card.

User-Replaceable VRLA Battery with Extended Runtime

Valve-regulated lead-acid batteries deliver 10.4 minutes of runtime at 1770W full load and 26.2 minutes at 885W half load. Batteries are user-replaceable for long-term serviceability. The unit operates from 32°F to 104°F and automatically restarts when utility power returns. It is not suited for environments outside this temperature range or for loads exceeding the 1960VA input rating.

Helstu kostir

  • Double-conversion topology delivers clean sine-wave power with zero transfer time
  • 4 minutes runtime at full 1770 W load protects critical workloads
  • User-replaceable VRLA batteries extend service life without technician visits
  • LCD interface shows real-time UPS status and site-power data at a glance
  • USB, RS-232, contact closure and optional SNMP card enable automated shutdowns

Tæknilýsing

BrandTRIPP LITE
SeriesSmartOnline
ModelSU3000XLCD
International Version120V
Input ConnectionNEMA 5-20P
VA Rating1960 VA
Watts1770 Watts
Output Voltage120V
Output Frequency50 / 60 Hz
Outlets7
Outlet Type(6) NEMA 5-20R; (1) NEMA L5-20R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load: 10.4 min. (1770W)
Half Load: 26.2 min. (885W)
Battery ReplaceableUser replaceable batteries
Interface Port(1) Contact closure; (1) RS-232; (1) Slot for SNMP/Web interface; (1) USB
Surge Energy Rating190 Joules
TemperatureOperating Temperature Range: 32° to 104°F (0° to 40°C)
Storage Temperature Range: With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C)
Humidity0-96% non-condensing
Dimensions13.63" x 8.43" x 16.23"
Weight73.42 lbs.
Sendingarþyngd34.93 kg
Stærð sendingar602 × 368 × 340 mm

Aðrar útgáfur af þessari vöru

3 í viðbót í sama vöruflokki

Sama fjölskylda, mismunandi minni, kælingu eða klukkuhraða — berðu saman áður en þú ákveður þig.

Spurningar um þessa vöru

What input plug does the SU3000XLCD use and what current can it draw?

The unit uses a NEMA 5-20P input plug rated for 20 A on a 120 V circuit.

What are the exact dimensions and weight for rack or shelf planning?

It measures 13.63" wide x 8.43" deep x 16.23" high and weighs 73.42 lbs.

How do you install the network management card without losing configuration access?

Power down the UPS, insert the optional SNMPWEBCARD into the dedicated slot, then power up and configure via USB or RS-232.