NEMIX RAM DDR5-5600 2TB (16x128GB) ECC RDIMM CL46 1.1V Supermicro H14SST-G memory upgrade
- 2TB (16 x 128GB)
- 288-Pin DDR5 RDIMM
Mēs pieņemam kriptovalūtu — lai tā, kas Jums pieder, varētu nopirkt īstu aparatūru.Maksājiet kriptovalūtā, iztērējiet to īstai aparatūrai. Bezmaksas apdrošināta piegāde visā pasaulē virs 399 $. Vienkāršas, nemarķētas kastes, sūtītas no Vācijas.Bezmaksas apdrošināta piegāde virs 399 $. Jūsu kurss tiek fiksēts uz 30 minūtēm, tiklīdz atveras kase.Kurss fiksēts uz 30 minūtēm. Katra prece ir aizzīmogota, tās sērijas numurs ir pārbaudīts, un uz to attiecas 24 mēnešu garantija.Aizzīmogots, 24 mēnešu garantija.
Mean Well
Delivers 24 V at 6.5 A (156 W) with active PFC, constant-current limiting, free-air convection cooling and a 5 V/0.3 A standby rail in a 1U low-profile chassis
The Mean Well HRPG-150-24 delivers a regulated 24 V output at 6.5 A for 156 W continuous power. It accepts a universal AC input and includes active power-factor correction. A 5 V standby rail supplies 0.3 A for auxiliary circuits. Cooling relies on free-air convection with no internal fan.
Installers who require remote on/off control or sub-0.5 W no-load draw should choose another model, as this variant omits those features. The unit fits 1U low-profile enclosures and survives 300 VAC surge events for five seconds. Built-in protections cover short circuit, overload, over-voltage and over-temperature.
This specification determines whether the supply matches the load and harmonic requirements of the installation. The constant-current limiting circuit and remote-sense terminals support stable voltage under varying cable lengths. A green LED indicates power-on status.
| Type | AT |
|---|
Mount the 1U low-profile unit with the convection vents facing open space; the common mistake is blocking the top or bottom airflow gaps with cables or a chassis panel, which stops the free-air cooling from working.
No scheduled maintenance is required; the only replaceable item is the internal fan-less thermal path — if dust builds up on the heatsink fins after years of use, clean it with compressed air to keep convection effective.
The over-temperature protection triggers first; the built-in constant-current limiting circuit holds output at 6.5A, but sustained full-load heat in a sealed enclosure will trip the thermal shutdown before any electrical limit is reached.
Arī šajā sadaļā
Tas pats plaukts, tā pati kase — astoņas kriptovalūtas un kursa fiksēšana uz 30 minūtēm.
Kriptovalūta, kurā maksājat, un valūta, kurā redzat cenas.
Nosūtīts no Jūsu maciņa, noformējot pasūtījumu
Tikai informatīvi — katalogā cenas norādītas ASV dolāros
Neviena valūta neatbilst.
Izvēlieties valodu, kurā vietne sarunājas ar Jums.
Pirmo reizi šeit?
Jau ir konts?
Automātiskas atiestatīšanas nav: šis veikals nesūta e-pastus, tāpēc nav arī vienreizējas saites, ko pieprasīt. Atstājiet adresi kontā, un tā tiks apstrādāta manuāli.
Pieprasījums saņemts
Uz Jūsu e-pastu nekas neatnāks — šis veikals vispār nesūta e-pastus. Kāds šos pieprasījumus apstrādā manuāli.
Atcerējāties?