Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
Mean Well
Delivers 24 V at 6.5 A (156 W) with active PFC, constant-current limiting, free-air convection cooling and a 5 V/0.3 A standby rail in a 1U low-profile chassis
The Mean Well HRPG-150-24 delivers a regulated 24 V output at 6.5 A for 156 W continuous power. It accepts a universal AC input and includes active power-factor correction. A 5 V standby rail supplies 0.3 A for auxiliary circuits. Cooling relies on free-air convection with no internal fan.
Installers who require remote on/off control or sub-0.5 W no-load draw should choose another model, as this variant omits those features. The unit fits 1U low-profile enclosures and survives 300 VAC surge events for five seconds. Built-in protections cover short circuit, overload, over-voltage and over-temperature.
This specification determines whether the supply matches the load and harmonic requirements of the installation. The constant-current limiting circuit and remote-sense terminals support stable voltage under varying cable lengths. A green LED indicates power-on status.
| Type | AT |
|---|
Mount the 1U low-profile unit with the convection vents facing open space; the common mistake is blocking the top or bottom airflow gaps with cables or a chassis panel, which stops the free-air cooling from working.
No scheduled maintenance is required; the only replaceable item is the internal fan-less thermal path — if dust builds up on the heatsink fins after years of use, clean it with compressed air to keep convection effective.
The over-temperature protection triggers first; the built-in constant-current limiting circuit holds output at 6.5A, but sustained full-load heat in a sealed enclosure will trip the thermal shutdown before any electrical limit is reached.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?