Prijímame kryptomeny — takže mince, ktoré držíte, môžete zameniť za skutočný hardvér.Plaťte v krypte, miňte ho na skutočný hardvér. Poistená doprava zadarmo po celom svete nad 399 $. Neutrálne kartóny bez potlače, odosielané z Nemecka.Poistená doprava zadarmo nad 399 $. Váš kurz je zablokovaný na 30 minút hneď po otvorení pokladne.Kurz zablokovaný na 30 minút. Každý produkt je zapečatený, jeho sériové číslo je overené a vzťahuje sa naň 24-mesačná záruka.Zapečatené, 24-mesačná záruka.
Mean Well
Delivers 24 V at 6.5 A (156 W) with active PFC, constant-current limiting, free-air convection cooling and a 5 V/0.3 A standby rail in a 1U low-profile chassis
The Mean Well HRPG-150-24 delivers a regulated 24 V output at 6.5 A for 156 W continuous power. It accepts a universal AC input and includes active power-factor correction. A 5 V standby rail supplies 0.3 A for auxiliary circuits. Cooling relies on free-air convection with no internal fan.
Installers who require remote on/off control or sub-0.5 W no-load draw should choose another model, as this variant omits those features. The unit fits 1U low-profile enclosures and survives 300 VAC surge events for five seconds. Built-in protections cover short circuit, overload, over-voltage and over-temperature.
This specification determines whether the supply matches the load and harmonic requirements of the installation. The constant-current limiting circuit and remote-sense terminals support stable voltage under varying cable lengths. A green LED indicates power-on status.
| Type | AT |
|---|
Mount the 1U low-profile unit with the convection vents facing open space; the common mistake is blocking the top or bottom airflow gaps with cables or a chassis panel, which stops the free-air cooling from working.
No scheduled maintenance is required; the only replaceable item is the internal fan-less thermal path — if dust builds up on the heatsink fins after years of use, clean it with compressed air to keep convection effective.
The over-temperature protection triggers first; the built-in constant-current limiting circuit holds output at 6.5A, but sustained full-load heat in a sealed enclosure will trip the thermal shutdown before any electrical limit is reached.
Aj v tomto oddelení
Rovnaké oddelenie, rovnaká pokladňa — osem mien a kurz zablokovaný na 30 minút.
Mena, v ktorej platíte, a mena, v ktorej sa zobrazujú ceny.
Odoslané z vašej peňaženky na pokladni
Len na zobrazenie — katalóg je uvedený v dolároch
Žiadna mena nezodpovedá.
Vyberte jazyk, v ktorom s vami bude web komunikovať.
Ste tu prvýkrát?
Účet už máte?
Automatický reset hesla neexistuje: tento obchod neposiela žiadne e-maily, takže neexistuje jednorazový odkaz, o ktorý by ste mohli požiadať. Nechajte adresu na účte — niekto sa jej ujme ručne.
Žiadosť zaznamenaná
Do vašej schránky nič nepríde — tento obchod neposiela vôbec žiadne e-maily. Niekto sa o to postará ručne.
Spomenuli ste si?