Mēs pieņemam kriptovalūtu — lai tā, kas Jums pieder, varētu nopirkt īstu aparatūru.Maksājiet kriptovalūtā, iztērējiet to īstai aparatūrai. Bezmaksas apdrošināta piegāde visā pasaulē virs 399 $. Vienkāršas, nemarķētas kastes, sūtītas no Vācijas.Bezmaksas apdrošināta piegāde virs 399 $. Jūsu kurss tiek fiksēts uz 30 minūtēm, tiklīdz atveras kase.Kurss fiksēts uz 30 minūtēm. Katra prece ir aizzīmogota, tās sērijas numurs ir pārbaudīts, un uz to attiecas 24 mēnešu garantija.Aizzīmogots, 24 mēnešu garantija.

Uzraudzītās preces Pieteikties

MINUTEMAN

MINUTEMAN RPM1516N1LCD-15P 16-Outlet Switched PDU 15A NEMA 5-15P 10ft

SKU CH-WGCN-2X02A MPN RPM1516N1LCD-15P

A 16-outlet switched PDU with network monitoring and individual outlet control for 15A rack power distribution

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current15A
  • Input Connector(s)NEMA 5-15P
  • Cord Length10 ft
  • 16 individually switched outlets let you reboot each device remotely
  • 15 A NEMA 5-15P input with 10 ft cord powers the unit from a standard rack feed
  • 0U vertical design fits 16 receptacles without using rack U-space
  • Built-in LCD and RJ-45 network port enable browser and SNMP monitoring
  • Centralised software manages up to 24 devices from one IP address

Switched PDU for 16 devices

The Minuteman RPM1516N1LCD-15P is a switched power distribution unit built for network administrators who need remote control over individual outlets. It provides sixteen NEMA 5-15R receptacles fed by a single NEMA 5-15P input plug rated at 15A. A ten-foot cord connects the unit to the upstream supply. The 0U vertical form factor mounts in a standard rack without consuming horizontal rack units.

Thermals noise and power draw

Passive power distribution generates no audible fan noise and adds negligible heat to the rack environment. The unit draws up to 15A from the branch circuit and distributes it across the sixteen outlets. An integrated LCD panel and network interface report real-time voltage, current, and power readings so operators can spot overload conditions before a breaker trips. Threshold alerts and email notifications support proactive thermal management.

Build integration needs and freedoms

The PDU requires a 15A NEMA 5-15R wall receptacle or UPS output and a CAT5 network drop for IP-based management. It frees administrators from physical site visits by enabling outlet-level power cycling, sequencing, and scheduling over SNMP or a web browser. Centralised software can monitor up to 24 devices from a single IP address, reducing the number of management ports needed in dense rack rows. The 62368-1 certification confirms compliance with safety standards for IT equipment.

Priekšrocības

  • 16 individually switched outlets let you reboot each device remotely
  • 15 A NEMA 5-15P input with 10 ft cord powers the unit from a standard rack feed
  • 0U vertical design fits 16 receptacles without using rack U-space
  • Built-in LCD and RJ-45 network port enable browser and SNMP monitoring
  • Centralised software manages up to 24 devices from one IP address

Specifikācijas

BrandMINUTEMAN
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current15A
Input Connector(s)NEMA 5-15P
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (16) 5-15 R
Sūtījuma svars4.99 kg
Sūtījuma izmēri1359 × 221 × 109 mm

Citas šī modeļa versijas

Vēl 5 šajā sērijā

Viena saime, taču atšķirīga atmiņa, dzesētājs vai frekvence — salīdziniet, pirms izlemjat.

Jautājumi par šo preci

How do I mount the 0U vertical PDU in my rack, and what is the common mistake installers make?

Mount the unit vertically along the side rails using the integrated brackets; the step often missed is leaving enough clearance for the 10 ft input cord to route without tension.

Which components will need replacement during the life of this switched PDU?

The internal relay modules that switch each of the 16 NEMA 5-15R outlets are the primary wear items and should be inspected after extended cycling.

What is the first limit reached when the PDU runs near capacity for long periods?

The 15 A maximum input current trips the internal breaker before any outlet-level threshold is hit.

Arī šajā sadaļā

Klienti arī salīdzināja

Tas pats plaukts, tā pati kase — astoņas kriptovalūtas un kursa fiksēšana uz 30 minūtēm.