MINUTEMAN RPM1524N1LCD-15P 24-outlet switched PDU NEMA 5-15P 15A 0U vertical
- Power Distribution…
- 0U Vertical Install…
MINUTEMAN
A 16-outlet switched PDU with network monitoring and individual outlet control for 15A rack power distribution
Model RPM1516N1LCD-15P
The Minuteman RPM1516N1LCD-15P is a switched power distribution unit built for network administrators who need remote control over individual outlets. It provides sixteen NEMA 5-15R receptacles fed by a single NEMA 5-15P input plug rated at 15A. A ten-foot cord connects the unit to the upstream supply. The 0U vertical form factor mounts in a standard rack without consuming horizontal rack units.
Passive power distribution generates no audible fan noise and adds negligible heat to the rack environment. The unit draws up to 15A from the branch circuit and distributes it across the sixteen outlets. An integrated LCD panel and network interface report real-time voltage, current, and power readings so operators can spot overload conditions before a breaker trips. Threshold alerts and email notifications support proactive thermal management.
The PDU requires a 15A NEMA 5-15R wall receptacle or UPS output and a CAT5 network drop for IP-based management. It frees administrators from physical site visits by enabling outlet-level power cycling, sequencing, and scheduling over SNMP or a web browser. Centralised software can monitor up to 24 devices from a single IP address, reducing the number of management ports needed in dense rack rows. The 62368-1 certification confirms compliance with safety standards for IT equipment.
| Brand | MINUTEMAN |
|---|---|
| Type | Power Distribution Units |
| Style | 0U Vertical Installation |
| Certifications | 62368-1 Certification |
| Maximum Input Current | 15A |
| Input Connector(s) | NEMA 5-15P |
| Cord Length | 10 ft |
| Output Connector(s) | Front Panel Receptacles: (16) 5-15 R |
| 배송 무게 | 4.99 kg |
| 포장 크기 | 1359 × 221 × 109 mm |
이 모델의 다른 버전
같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.
Mount the unit vertically along the side rails using the integrated brackets; the step often missed is leaving enough clearance for the 10 ft input cord to route without tension.
The internal relay modules that switch each of the 16 NEMA 5-15R outlets are the primary wear items and should be inspected after extended cycling.
The 15 A maximum input current trips the internal breaker before any outlet-level threshold is hit.
이 진열대의 다른 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
결제할 코인과 가격을 확인할 통화입니다.
체크아웃 시 지갑에서 전송됩니다.
표시 전용 — 카탈로그 가격은 달러 기준입니다.
일치하는 통화가 없습니다.
사이트에서 사용할 언어를 선택하십시오.
일치하는 언어가 없습니다.
처음 방문하셨나요?
이미 계정이 있으신가요?
자동 재설정 기능은 없습니다. 이 쇼핑몰은 어떠한 메일도 보내지 않으므로 요청할 일회용 링크 자체가 없습니다. 계정에 등록된 이메일 주소를 그대로 두시면 담당자가 직접 확인해 처리합니다.
요청 접수
받은편지함으로 오는 것은 아무것도 없습니다 — 이 쇼핑몰은 메일을 전혀 보내지 않습니다. 담당자가 직접 확인해 처리합니다.
기억나셨나요?