MINUTEMAN RPM1516N1LCD-HW PDU 16-outlet switched hardwired 0U vertical

SKU CH-K5T9-4WY84 MPN RPM1516N1LCD-HW

Switched PDU with 16 NEMA 5-15R outlets, hardwired input, 15 A capacity, IP-addressable remote management and local LCD monitoring

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current15A
  • Input Connector(s)Hardwire
  • Cord Length10 ft
  • Remotely reboot any of 16 outlets via web browser or SNMP
  • Hardwired 10 ft input with 15 A circuit breaker protects connected gear
  • 0U vertical form factor saves full rack height for servers
  • Local LCD shows real-time amps, IP address, temperature and humidity
  • Centralised software manages up to 24 devices from one IP address

Switched PDU for rack environments

The MINUTEMAN RPM1516N1LCD-HW is a 16-outlet switched power distribution unit built for vertical 0U rack mounting. It targets administrators who need remote outlet control and real-time monitoring of connected network gear. A hardwired input and ten-foot cord simplify permanent installation in cabinet rows.

15 A capacity with per-outlet switching

The unit accepts a maximum input current of 15 A and delivers the same rated output across sixteen NEMA 5-15R receptacles. An input circuit breaker provides overload protection for the whole strip. Headroom ends at the 15 A limit, so loads that exceed this rating will trip the breaker and require redistribution.

Hardwired input and IP-based management

A hardwire feed eliminates plug compatibility concerns in facilities with dedicated branch circuits. The built-in web server, SNMP support and LCD let operators toggle outlets, view amperage, temperature and humidity, and receive email or SNMP alerts without a separate console server. IPv4 and IPv6, SSH, RADIUS and role-based accounts secure remote access.

주요 특징

  • Remotely reboot any of 16 outlets via web browser or SNMP
  • Hardwired 10 ft input with 15 A circuit breaker protects connected gear
  • 0U vertical form factor saves full rack height for servers
  • Local LCD shows real-time amps, IP address, temperature and humidity
  • Centralised software manages up to 24 devices from one IP address

사양

BrandMINUTEMAN
ModelRPM1516N1LCD-HW
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current15A
Input Connector(s)Hardwire
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (16) 5-15 R
Maximum Output Current15A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
배송 무게4.99 kg
포장 크기1359 × 221 × 109 mm

이 모델의 다른 버전

같은 라인업에서 5개 더

같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.

이 상품에 대한 질문

Will the 15 A hard-wired input and 16 NEMA 5-15R outlets work with my existing 15 A rack circuit?

The unit draws a maximum of 15 A through its hard-wired 10 ft feed and provides 16 front-panel 5-15R receptacles, each protected by the built-in input circuit breaker, so it matches a standard 15 A branch circuit.

How can I confirm the PDU is operating correctly once installed?

The local LCD shows real-time amperage, IP address, temperature and humidity, while the built-in web server and SNMP traps send email or syslog alerts for overloads, threshold breaches and power events.

What ships with the PDU and what must I source separately?

The package includes the 0U vertical PDU with 10 ft hard-wired input cord; you must supply the CAT5 network cable for the 10/100 Base-T port and provide the hard-wire connection to your electrical panel.