저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

MINUTEMAN

MINUTEMAN RPM208N1LCD-20P PDU 8-outlet 20A 100-120V LCD IP-addressable 1U/0U

SKU CH-TX05-0Y5FX MPN RPM208N1LCD-20P

IP-addressable PDU with eight NEMA 5-15/20R outlets, 20 A breaker, local LCD metering and 10 ft NEMA 5-20P cord

  • TypePower Distribution Units
  • StyleHorizontal Installation, 0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current20A
  • Input Connector(s)NEMA 5-20P
  • Cord Length10 ft
  • Remote power control via IP-addressable manager
  • Real-time load monitoring on local LCD display
  • Flexible 1U rack or 0U vertical mounting
  • Eight NEMA 5-15/20R outlets with 20A breaker protection
  • Event alerts by email SNMP traps and syslog

Purpose-built power distribution

This IP-addressable PDU provides eight NEMA 5-15/20R outlets for rack-mounted equipment operating at 100-120VAC. It supports a maximum load of 16 amps with a 20-amp input breaker and installs in 1U horizontal or 0U vertical orientations. Network administrators gain remote on/off/reset control of individual receptacles through a built-in web server.

Thermals noise and power draw

The local LCD continuously reports real-time amperage, internal temperature and humidity without adding audible fans. A 10-foot NEMA 5-20P input cord delivers up to 20 amps from the branch circuit while the internal breaker protects against overloads. The unit carries 62368-1 safety certification for continuous operation in standard server-room environments.

Bundled management capabilities

The integrated 10/100 Base-T port enables IPv4 and IPv6 connectivity with SNMP v1/v2c/v3, SSH, Telnet and RADIUS authentication. Event notifications arrive via email, SNMP traps, syslog, LED or audible alarm. The firmware stores up to 5,000 entries each for power-consumption logs and event logs, and supports daily, weekly, monthly and yearly energy reporting. SSL-secured browser access and IP-address filtering complete the remote-management suite.

주요 특징

  • Remote power control via IP-addressable manager
  • Real-time load monitoring on local LCD display
  • Flexible 1U rack or 0U vertical mounting
  • Eight NEMA 5-15/20R outlets with 20A breaker protection
  • Event alerts by email SNMP traps and syslog

사양

BrandMINUTEMAN
ModelRPM208N1LCD-20P
TypePower Distribution Units
StyleHorizontal Installation, 0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current20A
Input Connector(s)NEMA 5-20P
Cord Length10 ft
Output Connector(s)Rear Panel Receptacles: (8) 5-15/20R
Maximum Output Current20A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
배송 무게3.63 kg
포장 크기505 × 211 × 89 mm

이 모델의 다른 버전

같은 라인업에서 5개 더

같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.

이 상품에 대한 질문

How do I mount the RPM208N1LCD-20P in a rack and which step is often missed?

The unit supports 1U horizontal or 0U vertical mounting; the step often missed is securing the rear mounting brackets for vertical 0U orientation to prevent torque on the NEMA 5-20P inlet.

What maintenance or replacement will the RPM208N1LCD-20P need over time?

The 20A input circuit breaker is the primary replaceable component; if it trips repeatedly under 16A max load, the breaker should be inspected and replaced to restore overload protection.

What is the first limit reached when the PDU runs at sustained load?

The 16-amp maximum continuous load rating is the first limit; exceeding it will trip the 20A breaker even though the outlets and cord are rated for 20A.