저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

MINUTEMAN

MINUTEMAN RPM208I2LCD-L20P 8-Outlet Switched PDU NEMA L6-20P 0U Vertical

SKU CH-1FD3-2KAJ7 MPN RPM208I2LCD-L20P

Switched vertical PDU with eight outlets, NEMA L6-20P input and IP-addressable remote management via built-in web server and SNMP

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current20A
  • Input Connector(s)NEMA L6-20P
  • Cord Length10 ft
  • Remote outlet switching via built-in web server
  • Local LCD shows real-time amps, IP, temperature, humidity
  • 20 A input circuit breaker protects connected equipment
  • 0U vertical form factor fits 24 outlets in zero rack units
  • 62368-1 certified for IT equipment safety compliance

0U Vertical Switched PDU for Rack Power Control

The MINUTEMAN RPM208I2LCD-L20P is an 8-outlet switched power distribution unit designed for vertical 0U rack mounting. It provides IP-addressable remote management of individual outlets, allowing administrators to power cycle connected network devices from a central interface. The unit includes a local LCD that reports current draw, IP address and environmental readings.

Check Input Connector

Verify that the facility supplies a NEMA L6-20P receptacle and that a 20 A circuit is available for the 10 ft input cord. The PDU connects to the management network through a 10/100 Base-T Ethernet port, so a free RJ-45 drop and IPv4 or IPv6 addressing must be planned. Ensure the rack can accommodate a vertical 0U form factor without blocking airflow to other equipment.

Circuit Breaker Protection

An integrated input circuit breaker provides overload protection for the 20 A maximum output current. The built-in LCD and remote interface display real-time amperage, temperature and humidity data, while SNMP traps and email alerts notify operators of threshold events. Power consumption logs store up to 5000 entries each for detailed auditing.

주요 특징

  • Remote outlet switching via built-in web server
  • Local LCD shows real-time amps, IP, temperature, humidity
  • 20 A input circuit breaker protects connected equipment
  • 0U vertical form factor fits 24 outlets in zero rack units
  • 62368-1 certified for IT equipment safety compliance

사양

BrandMINUTEMAN
ModelRPM208I2LCD-L20P
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current20A
Input Connector(s)NEMA L6-20P
Cord Length10 ft
Maximum Output Current20A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
배송 무게4.54 kg
포장 크기505 × 211 × 89 mm

이 모델의 다른 버전

같은 라인업에서 5개 더

같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.

이 상품에 대한 질문

What comes in the box with the RPM208I2LCD-L20P and what must I source separately?

The unit includes a 10 ft cord with a NEMA L6-20P plug and an LCD for local monitoring. You will need to provide a 20 A 208 V supply circuit, a rack or cabinet for 0U vertical mounting, and CAT5 cable for the 10/100 Base-T Ethernet port.

How do I decide between the LCD and EV6 versions of this switched PDU?

The LCD model adds a front-panel display that shows amps, IP address, temperature and humidity locally, while both versions share the same 20 A rating, 8 switched outlets, web interface, SNMP v1/v2c/v3, SSH, email/SNMP/syslog alerts and centralised software support.

What does the 20 A input rating mean once the PDU is installed in my rack?

The 20 A maximum input current limits the total load across all eight outlets to 20 A at 208 V. An internal circuit breaker protects the strip, and the LCD or web interface reports real-time aggregate amperage so you can stay within that limit.