저희는 암호화폐로 결제를 받습니다 — 보유하신 코인으로 실제 하드웨어를 구매하실 수 있습니다.암호화폐로 결제하고, 실제 하드웨어 구매에 사용하십시오. 전 세계 어디서나 US$399 이상 구매 시 무료 보험 배송. 무지 상자에 담아 독일에서 발송합니다.US$399 이상 구매 시 무료 보험 배송. 체크아웃을 시작하면 30분 동안 환율이 잠깁니다.30분간 환율 잠금. 모든 제품은 밀봉된 상태로 일련번호를 확인한 후 24개월 보증을 제공합니다.밀봉 포장, 24개월 보증.

가격 추적 로그인

MINUTEMAN

MINUTEMAN RPM1524N1LCD-HW PDU 24-outlet 15A hardwired 0U vertical switched

SKU CH-JSMM-K8V8P MPN RPM1524N1LCD-HW

Switched 0U vertical PDU with 24 NEMA 5-15R outlets, hardwired 15 A input, built-in web server and LCD for remote outlet control and power monitoring

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current15A
  • Input Connector(s)Hardwire
  • Cord Length10 ft
  • Remote reboot of 24 outlets via single IP address
  • Local LCD shows real-time amps IP temperature humidity
  • Hardwired 15 A input with 10 ft cord for permanent rack power
  • 0U vertical design fits 24 NEMA 5-15R outlets in zero rack units
  • Built-in web server SNMP email alerts for full remote monitoring

Hardwired 15A PDU for Rack Power Control

The Minuteman RPM1524N1LCD-HW is a switched power distribution unit built for hardwired 15A input. It provides 24 NEMA 5-15R outlets in a 0U vertical form factor for rack mounting. An integrated LCD shows real-time current, IP address, temperature and humidity readings. Remote management is handled through a built-in web server, SNMP and email alerts.

Suited for Admins Needing Outlet-Level Switching

Network managers who must reboot individual servers or cycle power on attached gear from a single IP address will use the per-outlet control and power-sequencing features. Environments that cannot hardwire the feed or that require a different outlet type or higher input current should consider other units. Buyers without rack infrastructure or without SNMP monitoring in place will not use the core capabilities.

24 NEMA 5-15R Outlets on a Hardwired 15A Feed

The unit delivers 24 front-panel 5-15R receptacles fed by a 10 ft hardwired cord rated for 15A maximum input and output. Input circuit-breaker protection guards against overload. This outlet count and connector mix is the deciding factor for compatibility with existing rack gear.

주요 특징

  • Remote reboot of 24 outlets via single IP address
  • Local LCD shows real-time amps IP temperature humidity
  • Hardwired 15 A input with 10 ft cord for permanent rack power
  • 0U vertical design fits 24 NEMA 5-15R outlets in zero rack units
  • Built-in web server SNMP email alerts for full remote monitoring

사양

BrandMINUTEMAN
ModelRPM1524N1LCD-HW
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current15A
Input Connector(s)Hardwire
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (24) 5-15 R
Maximum Output Current15A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
배송 무게6.80 kg
포장 크기1890 × 221 × 109 mm

이 모델의 다른 버전

같은 라인업에서 5개 더

같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.

이 상품에 대한 질문

How is the input circuit breaker on this 15 A PDU reset after an overload trip?

The unit uses an input circuit breaker for overload protection; after a trip the breaker handle on the chassis is manually reset once the load drops below 15 A.

What limits continuous operation first on the 24 NEMA 5-15R outlets fed by a 15 A hardwired input?

The 15 A input circuit breaker is the first limit; total draw across all 24 outlets must stay at or below 15 A or the breaker will trip.

Does the LCD and network interface add audible noise or extra heat when the PDU runs 24/7?

The PDU has no fans; the LCD and 10/100 Ethernet port draw minimal power, so added heat and noise are negligible in a rack.

이 진열대의 다른 상품