MINUTEMAN RPM3024I2LCD-L30P PDU Switched 24-Outlet 208V 30A NEMA L5-30P 21×C13 3×C19 0U Vertical
- Power Distribution…
- 0U Vertical Install…
Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
MINUTEMAN
Switched 0U vertical PDU with 24 NEMA 5-15R outlets, hardwired 15 A input, built-in web server and LCD for remote outlet control and power monitoring
Model RPM1524N1LCD-HW
The Minuteman RPM1524N1LCD-HW is a switched power distribution unit built for hardwired 15A input. It provides 24 NEMA 5-15R outlets in a 0U vertical form factor for rack mounting. An integrated LCD shows real-time current, IP address, temperature and humidity readings. Remote management is handled through a built-in web server, SNMP and email alerts.
Network managers who must reboot individual servers or cycle power on attached gear from a single IP address will use the per-outlet control and power-sequencing features. Environments that cannot hardwire the feed or that require a different outlet type or higher input current should consider other units. Buyers without rack infrastructure or without SNMP monitoring in place will not use the core capabilities.
The unit delivers 24 front-panel 5-15R receptacles fed by a 10 ft hardwired cord rated for 15A maximum input and output. Input circuit-breaker protection guards against overload. This outlet count and connector mix is the deciding factor for compatibility with existing rack gear.
| Brand | MINUTEMAN |
|---|---|
| Model | RPM1524N1LCD-HW |
| Type | Power Distribution Units |
| Style | 0U Vertical Installation |
| Certifications | 62368-1 Certification |
| Maximum Input Current | 15A |
| Input Connector(s) | Hardwire |
| Cord Length | 10 ft |
| Output Connector(s) | Front Panel Receptacles: (24) 5-15 R |
| Maximum Output Current | 15A |
| Overload Protection | Input Circuit Breaker Protection |
| Features | IP-addressable Remote Power Manager Built-in Web Server to support Remote Power Management Event Notifications via Email or SNMP Traps Local LCD displays Amps, IP Address, Temperature and/or Humidity Daily, Weekly, Monthly & Yearly Power Consumption Data 10/100 Base-T Ethernet Port IPv4, IPv6 Support and SNMP Support (v1,v2c,v3) Telnet, SSH Encryption Support Radius Authentication User Account for Three Different Permissions Management Systems Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm SSL Web Browser for Set Up and Operation IP Address Filtering Maximum 5,000 E |
| Forsendelsesvægt | 6.80 kg |
| Pakkestørrelse | 1890 × 221 × 109 mm |
Andre versioner af denne model
Samme familie, men med anden hukommelse, køler eller clockfrekvens — sammenlign, før du bestemmer dig.
The unit uses an input circuit breaker for overload protection; after a trip the breaker handle on the chassis is manually reset once the load drops below 15 A.
The 15 A input circuit breaker is the first limit; total draw across all 24 outlets must stay at or below 15 A or the breaker will trip.
The PDU has no fans; the LCD and 10/100 Ethernet port draw minimal power, so added heat and noise are negligible in a rack.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ingen sprog matcher.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?