Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.

Prisvagt Log ind

MINUTEMAN

MINUTEMAN RPM158N1LCD-IEC PDU 12A 15A 100-120V 8-outlet IEC 10ft LCD IP-addressable

SKU CH-TNNT-JWSKQ MPN RPM158N1LCD-IEC

Eight-outlet PDU with IP-addressable remote on/off control, local LCD monitoring, and 10-foot IEC input cord

  • TypePower Distribution Units
  • StyleHorizontal Installation, 0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current15A
  • Input Connector(s)IEC
  • Cord Length10 ft
  • IP-addressable control lets you manage outlets from anywhere
  • Local LCD shows amps, IP address, temperature and humidity at a glance
  • 15 A circuit breaker protects connected equipment from overloads
  • 10 ft IEC input cord gives flexible rack placement
  • 8 NEMA 5-15R outlets support up to 12 A continuous load

IP-addressable PDU with local LCD

The Minuteman RPM158N1LCD-IEC is a 1U or 0U power distribution unit that provides eight NEMA 5-15R outlets. It supports a maximum load of 12 amps and includes a 15-amp input circuit breaker for overload protection. Network connectivity allows remote on, off, or reset control of each receptacle from a built-in web server.

100-120 VAC input with IEC connector

The unit accepts 100 to 120 VAC through an IEC inlet on a 10-foot cord and is rated for a maximum input current of 15 amps. Total connected equipment must not exceed the 12-amp continuous load limit. The 15-amp breaker protects the PDU and downstream devices from sustained over-current conditions.

Check outlet count and network management needs

Verify that eight 5-15R receptacles match the plug types and quantity required by your rack gear. Confirm that your management platform can use SNMP v1, v2c, or v3, SSH, or a web browser for monitoring and alerts. The LCD shows local amperage, IP address, temperature, and humidity readings without network access.

Fordele

  • IP-addressable control lets you manage outlets from anywhere
  • Local LCD shows amps, IP address, temperature and humidity at a glance
  • 15 A circuit breaker protects connected equipment from overloads
  • 10 ft IEC input cord gives flexible rack placement
  • 8 NEMA 5-15R outlets support up to 12 A continuous load

Specifikationer

BrandMINUTEMAN
ModelRPM158N1LCD-IEC
TypePower Distribution Units
StyleHorizontal Installation, 0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current15A
Input Connector(s)IEC
Cord Length10 ft
Output Connector(s)Rear Panel Receptacles: (8) 5-15R
Maximum Output Current15A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
Forsendelsesvægt3.18 kg
Pakkestørrelse505 × 211 × 89 mm

Andre versioner af denne model

5 flere i samme serie

Samme familie, men med anden hukommelse, køler eller clockfrekvens — sammenlign, før du bestemmer dig.

Spørgsmål om denne vare

Should I pick the 12 A max load or the 15 A breaker version?

The unit has a single 12 A maximum load rating and a 15 A input circuit breaker; choose it when your total connected equipment stays at or below 12 A continuous.

What does the 12 A max load mean once the PDU is rack-mounted and powered?

It is the continuous current you can draw across all eight NEMA 5-15R outlets combined without tripping the 15 A breaker, so plan your device loads to stay under that 12 A limit.

How does the IEC input connector and 15 A breaker cap real-world use?

The IEC inlet connects to a 100-120 VAC source through the 10 ft cord, and the 15 A breaker will trip if total draw exceeds 15 A, while the management firmware enforces the 12 A operational ceiling.

Også på denne hylde

Kunderne har også sammenlignet disse

Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.