Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
MINUTEMAN
An IP-addressable PDU with eight 5-15R outlets, 12 A maximum load, 15 A breaker, local LCD read-out and 10 ft IEC320 C20 input cord
Model RPM158N1LCD
The Minuteman RPM158N1LCD is a rack-mount power distribution unit that delivers eight NEMA 5-15R outlets from a single IEC320 C20 inlet. It supports both 1U horizontal and 0U vertical mounting so it fits standard racks or cabinet side rails. An integrated LCD shows real-time current, IP address and environmental readings. The unit is rated for a maximum load of 12 amps with a 15-amp input breaker.
This PDU adds IP-addressable outlet switching so administrators can power-cycle individual devices from anywhere. The jump is worth it when you manage servers or network gear that occasionally lock up and need a hard reboot without a site visit. Built-in web server, SNMP traps and email alerts provide automated event notification. Daily, weekly, monthly and yearly consumption logs store up to 5000 entries each for capacity planning.
Your rack must supply a 100-120VAC source with an IEC320 C20 connector to match the 10-foot input cord. Confirm the upstream circuit can deliver 15 amps so the internal breaker does not nuisance-trip. A 10/100 Base-T Ethernet drop is required for the management interface, which supports IPv4, IPv6, SNMP v1/v2c/v3, SSH and RADIUS authentication. Verify that your monitoring system can consume SNMP traps or syslog messages for alarm integration.
| Brand | MINUTEMAN |
|---|---|
| Model | RPM158N1LCD |
| Type | Power Distribution Units |
| Style | Horizontal Installation, 0U Vertical Installation |
| Certifications | 62368-1 Certification |
| Maximum Input Current | 15A |
| Input Connector(s) | IEC320 C20 |
| Cord Length | 10 ft |
| Output Connector(s) | Rear Panel Receptacles: (8) 5-15R |
| Maximum Output Current | 15A |
| Overload Protection | Input Circuit Breaker Protection |
| Features | IP-addressable Remote Power Manager Built-in Web Server to support Remote Power Management Event Notifications via Email or SNMP Traps Local LCD displays Amps, IP Address, Temperature and/or Humidity Daily, Weekly, Monthly & Yearly Power Consumption Data 10/100 Base-T Ethernet Port IPv4, IPv6 Support and SNMP Support (v1,v2c,v3) Telnet, SSH Encryption Support Radius Authentication User Account for Three Different Permissions Management Systems Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm SSL Web Browser for Set Up and Operation IP Address Filtering Maximum 5,000 E |
| Forsendelsesvægt | 2.72 kg |
| Pakkestørrelse | 505 × 211 × 89 mm |
Andre versioner af denne model
Samme familie, men med anden hukommelse, køler eller clockfrekvens — sammenlign, før du bestemmer dig.
The unit fits in 1U of horizontal rack space or mounts in 0U vertical orientation and connects via an IEC320 C20 inlet on a 10 ft cord.
Assign a static IPv4 or IPv6 address through the front LCD or a serial console, then link the 10/100 Base-T Ethernet port to your management VLAN.
Export or clear the logs through the web interface or scheduled SNMP pulls before the circular buffer overwrites the oldest 5,000 records.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ingen sprog matcher.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?