我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

MINUTEMAN

MINUTEMAN RPM1516N1LCD-15P 16-Outlet Switched PDU 15A NEMA 5-15P 10ft

SKU CH-WGCN-2X02A MPN RPM1516N1LCD-15P

A 16-outlet switched PDU with network monitoring and individual outlet control for 15A rack power distribution

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current15A
  • Input Connector(s)NEMA 5-15P
  • Cord Length10 ft
  • 16 individually switched outlets let you reboot each device remotely
  • 15 A NEMA 5-15P input with 10 ft cord powers the unit from a standard rack feed
  • 0U vertical design fits 16 receptacles without using rack U-space
  • Built-in LCD and RJ-45 network port enable browser and SNMP monitoring
  • Centralised software manages up to 24 devices from one IP address

Switched PDU for 16 devices

The Minuteman RPM1516N1LCD-15P is a switched power distribution unit built for network administrators who need remote control over individual outlets. It provides sixteen NEMA 5-15R receptacles fed by a single NEMA 5-15P input plug rated at 15A. A ten-foot cord connects the unit to the upstream supply. The 0U vertical form factor mounts in a standard rack without consuming horizontal rack units.

Thermals noise and power draw

Passive power distribution generates no audible fan noise and adds negligible heat to the rack environment. The unit draws up to 15A from the branch circuit and distributes it across the sixteen outlets. An integrated LCD panel and network interface report real-time voltage, current, and power readings so operators can spot overload conditions before a breaker trips. Threshold alerts and email notifications support proactive thermal management.

Build integration needs and freedoms

The PDU requires a 15A NEMA 5-15R wall receptacle or UPS output and a CAT5 network drop for IP-based management. It frees administrators from physical site visits by enabling outlet-level power cycling, sequencing, and scheduling over SNMP or a web browser. Centralised software can monitor up to 24 devices from a single IP address, reducing the number of management ports needed in dense rack rows. The 62368-1 certification confirms compliance with safety standards for IT equipment.

商品特色

  • 16 individually switched outlets let you reboot each device remotely
  • 15 A NEMA 5-15P input with 10 ft cord powers the unit from a standard rack feed
  • 0U vertical design fits 16 receptacles without using rack U-space
  • Built-in LCD and RJ-45 network port enable browser and SNMP monitoring
  • Centralised software manages up to 24 devices from one IP address

商品規格

BrandMINUTEMAN
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current15A
Input Connector(s)NEMA 5-15P
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (16) 5-15 R
出貨重量4.99 kg
包裝尺寸1359 × 221 × 109 mm

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

How do I mount the 0U vertical PDU in my rack, and what is the common mistake installers make?

Mount the unit vertically along the side rails using the integrated brackets; the step often missed is leaving enough clearance for the 10 ft input cord to route without tension.

Which components will need replacement during the life of this switched PDU?

The internal relay modules that switch each of the 16 NEMA 5-15R outlets are the primary wear items and should be inspected after extended cycling.

What is the first limit reached when the PDU runs near capacity for long periods?

The 15 A maximum input current trips the internal breaker before any outlet-level threshold is hit.

同類商品

顧客也比較過

同一分類,同一套結帳流程 — 支援八種加密貨幣,匯率鎖定 30 分鐘。