我們接受加密貨幣付款 — 讓您持有的幣種也能買到真正的硬體設備。以加密貨幣付款,直接購入真正的硬體設備。 全球訂單滿 US$399,即享免費保險運送。簡約外箱,不印任何品牌標誌,從德國出貨。訂單滿 US$399,即享免費保險運送。 結帳一開始,您的匯率即鎖定 30 分鐘。匯率鎖定 30 分鐘。 每件商品皆原廠密封、序號經過核對,並享有 24 個月保固。原廠密封,保固 24 個月。

追蹤清單 登入

MINUTEMAN

MINUTEMAN RPM1524N1LCD-IEC PDU Switched 24x5-15R IEC 15A 10ft 0U Vertical

SKU CH-ZF5G-FF13P MPN RPM1524N1LCD-IEC

A switched 0U vertical PDU with 24 NEMA 5-15R outlets, IEC input, 10 ft cord, 15 A rating, local LCD monitoring and IP-addressable remote outlet control

  • TypePower Distribution Units
  • Style0U Vertical Installation
  • Certifications62368-1 Certification
  • Maximum Input Current15A
  • Input Connector(s)IEC
  • Cord Length10 ft
  • Remote reboot of 24 outlets via single IP address
  • Local LCD shows real-time amps, IP, temperature and humidity
  • 10 ft IEC input cord with 15 A circuit-breaker protection
  • 0U vertical mounting saves rack space for 24 NEMA 5-15R receptacles
  • Built-in web server and SNMP enable browser or network management

Switched PDU with 24 NEMA 5-15R Outlets

This MINUTEMAN RPM1524N1LCD-IEC is a switched power distribution unit built for 0U vertical rack mounting. It delivers 24 front-panel NEMA 5-15R receptacles fed by a 10 ft IEC input cord rated for 15 A maximum current. The integrated LCD shows real-time amperage, IP address, temperature and humidity. Network administrators can control each outlet individually over IP for remote reboot and power sequencing.

Installation and Common Issues

The 0U vertical form factor fits standard rack uprights without consuming rack units, and the 10 ft cord reaches most facility PDUs or UPS outputs. Mounting hardware is included for vertical orientation only. The input circuit breaker provides overload protection but will trip if total draw exceeds 15 A, so verify aggregate load before powering all 24 outlets. Initial network configuration requires a wired Ethernet connection to the 10/100 Base-T port for web or SSH access.

Pre-Order Compatibility Checks

Confirm your rack depth and upright spacing accommodate a full-height 0U vertical chassis. Ensure the upstream power source presents an IEC connector compatible with the unit's input plug and can supply up to 15 A at the required voltage. Verify that connected equipment uses NEMA 5-15P plugs and that combined load stays within the 15 A branch-circuit limit. Network infrastructure must support IPv4 or IPv6 with SNMP v1, v2c or v3 for monitoring integration.

商品特色

  • Remote reboot of 24 outlets via single IP address
  • Local LCD shows real-time amps, IP, temperature and humidity
  • 10 ft IEC input cord with 15 A circuit-breaker protection
  • 0U vertical mounting saves rack space for 24 NEMA 5-15R receptacles
  • Built-in web server and SNMP enable browser or network management

商品規格

BrandMINUTEMAN
ModelRPM1524N1LCD-IEC
TypePower Distribution Units
Style0U Vertical Installation
Certifications62368-1 Certification
Maximum Input Current15A
Input Connector(s)IEC
Cord Length10 ft
Output Connector(s)Front Panel Receptacles: (24) 5-15 R
Maximum Output Current15A
Overload ProtectionInput Circuit Breaker Protection
FeaturesIP-addressable Remote Power Manager
Built-in Web Server to support Remote Power Management
Event Notifications via Email or SNMP Traps
Local LCD displays Amps, IP Address, Temperature and/or Humidity
Daily, Weekly, Monthly & Yearly Power Consumption Data
10/100 Base-T Ethernet Port
IPv4, IPv6 Support and SNMP Support (v1,v2c,v3)
Telnet, SSH Encryption Support
Radius Authentication
User Account for Three Different Permissions Management Systems
Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm
SSL Web Browser for Set Up and Operation
IP Address Filtering
Maximum 5,000 E
出貨重量6.80 kg
包裝尺寸1890 × 221 × 109 mm

其他版本

同系列還有 5 款

同系列產品,記憶體、散熱器或時脈不同 — 下單前請先比較。

商品問答

How can I confirm the PDU is operating correctly once installed?

The local LCD will show real-time amperage, the assigned IP address, and temperature or humidity readings, while the built-in web server lets you verify each of the 24 outlets responds to on/off commands.

What ships with the unit and what must I source separately?

The package includes the vertical 0U PDU with a 10 ft IEC input cord; you will need to supply a CAT5 network cable for the 10/100 Ethernet port and IEC-compatible upstream power.

Which capacity matches a 15 A single-phase rack circuit?

This model is rated for a maximum input and output current of 15 A and provides 24 NEMA 5-15R receptacles, making it the correct choice for a standard 15 A branch circuit.