Kami menerima kripto — jadi koin yang anda simpan boleh membeli perkakasan sebenar.Bayar dengan kripto, belanjakannya untuk perkakasan sebenar. Penghantaran berinsurans percuma ke seluruh dunia untuk belian melebihi USD 399. Kotak biasa tanpa jenama, dihantar dari Jerman.Penghantaran berinsurans percuma untuk belian melebihi USD 399. Kadar anda dikunci selama 30 minit sebaik sahaja proses pesanan bermula.Kadar dikunci selama 30 minit. Setiap item disegel, nombor sirinya disemak, dan dilindungi waranti 24 bulan.Disegel, waranti 24 bulan.

Barang disimpan Log masuk

CyberPower

CyberPower PR2200RTXL2UACN 2200VA 2200W 2U UPS

SKU CH-90KC-P0QC3 MPN PR2200RTXL2UACN

A 2200 VA line-interactive UPS delivers sine-wave output, 16 minutes runtime at half load and 2430 joules surge protection in a 2U rackmount chassis

  • International Version120V
  • Input Voltage Range70 - 155 VAC
  • Input Frequency47 - 63 Hz
  • Input ConnectionNEMA L5-30P
  • VA Rating2200 VA
  • Watts2200 W
  • 2200 VA and 2200 W capacity powers critical servers and network gear
  • Pure sine-wave output protects sensitive equipment from unexpected shutdowns
  • 8 NEMA 5-20R outlets deliver surge-protected battery backup for multiple devices
  • 1 minutes runtime at half load keeps systems running during outages
  • Automatic Voltage Regulation corrects fluctuations without draining the battery

Rack/Tower Convertible UPS

The CyberPower PR2200RTXL2UACN is a line-interactive uninterruptible power supply rated at 2200 VA and 2200 W. It delivers a pure sine wave output at 100/110/120 VAC to protect sensitive servers, networking gear and workstations from power gaps. The unit operates in either rackmount or tower orientation to fit different installation spaces.

2U Rackmount Build and Connections

A 2U rackmountable chassis houses sealed lead-acid batteries that recharge from empty to ninety percent in three hours. The input connects via a ten-foot cord ending in a NEMA L5-30P plug, while eight NEMA 5-20R outlets provide surge-protected battery backup for attached devices. Serial and dry-contact ports enable integration with management software for automated alerts and graceful shutdowns.

Replaces Basic Backup Units

This UPS upgrades setups that rely on simulated sine wave or standby topologies which can cause unexpected shutdowns on sensitive loads. The jump is worth it when equipment requires clean sine wave output, longer runtime at half load, or remote monitoring through serial and dry-contact interfaces. It does not suit buyers who need higher wattage capacity or extended runtime beyond the rated minutes.

Ciri-ciri utama

  • 2200 VA and 2200 W capacity powers critical servers and network gear
  • Pure sine-wave output protects sensitive equipment from unexpected shutdowns
  • 8 NEMA 5-20R outlets deliver surge-protected battery backup for multiple devices
  • 1 minutes runtime at half load keeps systems running during outages
  • Automatic Voltage Regulation corrects fluctuations without draining the battery

Spesifikasi

BrandCyberPower
ModelPR2200RTXL2UACN
International Version120V
Input Voltage Range70 - 155 VAC
Input Frequency47 - 63 Hz
Input ConnectionNEMA L5-30P
VA Rating2200 VA
Watts2200 W
Output Voltage100/110/120 VAC +/- 5%
Output Frequency50/60 Hz +/- 1%
Outlets8
Outlet Type8 x NEMA 5-20R
Battery TypeSealed Lead Acid
Battery Run TimeRuntime at Full Load: 6.3 min
Runtime at Half Load: 16 min
Battery Recharge Time3 Hours (0% to 90% charged)
Battery ReplaceableRB1260X8
AlarmsBattery Mode
Low Battery
Overload
Overcharge
Overheat
Interface Port1 Serial, 1 Dry Contact
Rackmountable2U
Surge Energy Rating2430 Joules
ProtectionInternal Circuitry Limiting
Circuit Breaker Protected
TemperatureOperating Temperature: 32 - 104 °F (0 - 40 °C)
Storage Temperature: 5 - 113 °F (-15 - 45 °C)
HumidityOperating Relative Humidity: 0 - 95 % (non-condensing)
Storage Relative Humidity: 0 - 95% (non-condensing)
Dimensions17.1" x 3.4 " x 24.8"
Weight93 lbs.
Berat penghantaran50.21 kg
Dimensi bungkusan765 × 574 × 274 mm

Soalan tentang produk ini

What input voltage range and frequency does the NEMA L5-30P connection accept?

The NEMA L5-30P input accepts 70 to 155 VAC at 47 to 63 Hz, matching the 120 V international version.

How much rack height does the 2U form factor require, and what outlet clearance is needed?

The unit occupies 2U of rack height; the rear panel provides eight NEMA 5-20R outlets that need cable-bend space behind the rack.

Which cables attach first during installation to avoid overload alarms?

Connect the NEMA L5-30P input cord to a 30 A branch circuit first, then plug loads into the eight NEMA 5-20R outlets so the UPS powers on before the equipment.

Juga di rak ini

Pelanggan turut membandingkan