CyberPower
CyberPower PR2200RTXL2UACN 2200VA 2200W 2U UPS
A 2200 VA line-interactive UPS delivers sine-wave output, 16 minutes runtime at half load and 2430 joules surge protection in a 2U rackmount chassis
- International Version120V
- Input Voltage Range70 - 155 VAC
- Input Frequency47 - 63 Hz
- Input ConnectionNEMA L5-30P
- VA Rating2200 VA
- Watts2200 W
- 2200 VA and 2200 W capacity powers critical servers and network gear
- Pure sine-wave output protects sensitive equipment from unexpected shutdowns
- 8 NEMA 5-20R outlets deliver surge-protected battery backup for multiple devices
- 1 minutes runtime at half load keeps systems running during outages
- Automatic Voltage Regulation corrects fluctuations without draining the battery
Rack/Tower Convertible UPS
The CyberPower PR2200RTXL2UACN is a line-interactive uninterruptible power supply rated at 2200 VA and 2200 W. It delivers a pure sine wave output at 100/110/120 VAC to protect sensitive servers, networking gear and workstations from power gaps. The unit operates in either rackmount or tower orientation to fit different installation spaces.
2U Rackmount Build and Connections
A 2U rackmountable chassis houses sealed lead-acid batteries that recharge from empty to ninety percent in three hours. The input connects via a ten-foot cord ending in a NEMA L5-30P plug, while eight NEMA 5-20R outlets provide surge-protected battery backup for attached devices. Serial and dry-contact ports enable integration with management software for automated alerts and graceful shutdowns.
Replaces Basic Backup Units
This UPS upgrades setups that rely on simulated sine wave or standby topologies which can cause unexpected shutdowns on sensitive loads. The jump is worth it when equipment requires clean sine wave output, longer runtime at half load, or remote monitoring through serial and dry-contact interfaces. It does not suit buyers who need higher wattage capacity or extended runtime beyond the rated minutes.
נקודות עיקריות
- 2200 VA and 2200 W capacity powers critical servers and network gear
- Pure sine-wave output protects sensitive equipment from unexpected shutdowns
- 8 NEMA 5-20R outlets deliver surge-protected battery backup for multiple devices
- 1 minutes runtime at half load keeps systems running during outages
- Automatic Voltage Regulation corrects fluctuations without draining the battery
מפרט טכני
| Brand | CyberPower |
|---|---|
| Model | PR2200RTXL2UACN |
| International Version | 120V |
| Input Voltage Range | 70 - 155 VAC |
| Input Frequency | 47 - 63 Hz |
| Input Connection | NEMA L5-30P |
| VA Rating | 2200 VA |
| Watts | 2200 W |
| Output Voltage | 100/110/120 VAC +/- 5% |
| Output Frequency | 50/60 Hz +/- 1% |
| Outlets | 8 |
| Outlet Type | 8 x NEMA 5-20R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Runtime at Full Load: 6.3 min Runtime at Half Load: 16 min |
| Battery Recharge Time | 3 Hours (0% to 90% charged) |
| Battery Replaceable | RB1260X8 |
| Alarms | Battery Mode Low Battery Overload Overcharge Overheat |
| Interface Port | 1 Serial, 1 Dry Contact |
| Rackmountable | 2U |
| Surge Energy Rating | 2430 Joules |
| Protection | Internal Circuitry Limiting Circuit Breaker Protected |
| Temperature | Operating Temperature: 32 - 104 °F (0 - 40 °C) Storage Temperature: 5 - 113 °F (-15 - 45 °C) |
| Humidity | Operating Relative Humidity: 0 - 95 % (non-condensing) Storage Relative Humidity: 0 - 95% (non-condensing) |
| Dimensions | 17.1" x 3.4 " x 24.8" |
| Weight | 93 lbs. |
| משקל משלוח | 50.21 kg |
| מידות האריזה | 765 × 574 × 274 mm |
שאלות על הפריט הזה
What input voltage range and frequency does the NEMA L5-30P connection accept?
The NEMA L5-30P input accepts 70 to 155 VAC at 47 to 63 Hz, matching the 120 V international version.
How much rack height does the 2U form factor require, and what outlet clearance is needed?
The unit occupies 2U of rack height; the rear panel provides eight NEMA 5-20R outlets that need cable-bend space behind the rack.
Which cables attach first during installation to avoid overload alarms?
Connect the NEMA L5-30P input cord to a 30 A branch circuit first, then plug loads into the eight NEMA 5-20R outlets so the UPS powers on before the equipment.