OEM Industries
OEM Industries 6025 KDE1206PTV1 MS.AF.GN 12V 1.7W 3Wire Cooling Fan
Pack of twenty 60 by 25 millimetre 12 volt 1.7 watt three-wire cooling fans
- Pack of twenty fans simplifies bulk builds
- Sunon 60 mm x 25 mm frame fits standard mounts
- 12 V 1.7 W rating keeps power draw low
- Three-wire connector enables speed monitoring
- 6025 KDE1206PTV1 model ensures exact replacement
20-piece SUNON 60×25 mm fan lot
This lot supplies twenty SUNON 60×25 mm fans identified as KDE1206PTV1 MS.AF.GN. Each unit runs on 12 V and draws 1.7 W through a three-wire lead. The pack is aimed at system integrators or maintenance teams needing a quantity of identical replacement coolers.
Suited for 12 V three-wire headers
These fans suit builds that use a standard 12 V three-wire header and accept a 60 mm frame with 25 mm thickness. Buyers who need PWM speed control, a different voltage, a larger frame or a smaller quantity should look elsewhere.
12 V 1.7 W three-wire electrical spec
The decisive specification is the 12 V 1.7 W three-wire electrical interface. Confirm that your motherboard or controller provides a matching 12 V header and that the 6025 form factor fits the intended mounting points before ordering.
Ciri-ciri utama
- Pack of twenty fans simplifies bulk builds
- Sunon 60 mm x 25 mm frame fits standard mounts
- 12 V 1.7 W rating keeps power draw low
- Three-wire connector enables speed monitoring
- 6025 KDE1206PTV1 model ensures exact replacement
Spesifikasi
Belum ada spesifikasi diterbitkan untuk produk ini.
Soalan tentang produk ini
How do I install the 6025 fan and which wire is often connected incorrectly?
Mount the 60 × 25 mm frame with four screws, connect the red wire to 12 V, black to ground, and the yellow wire to the motherboard tachometer header; the yellow lead is the one most often left loose.
What maintenance will the 6025 KDE1206PTV1 need over time?
Clean dust from the blades and heatsink fins every few months with compressed air; the sleeve bearing cannot be relubricated, so plan to replace the fan when noise or vibration increases.
What limit appears first when the 6025 runs continuously at 12 V?
The 1.7 W motor draws a fixed current, so the sleeve bearing temperature rises until thermal expansion increases friction, making bearing wear the first sustained-use limit.