CyberPower OR500LCDRM1U 500VA 300W 1U Rackmount UPS
- 90 - 140 Volts AC
- 57 - 63 Hz
Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.
CyberPower
1U rackmount UPS delivering 1500 VA / 900 W with six outlets, LCD diagnostics, AVR and network surge protection
The CyberPower OR1500LCDRM1U is a 1U rackmount battery backup rated at 1500 VA and 900 W. It provides simulated sine wave output for up to six connected devices through NEMA 5-15R outlets. Four outlets deliver both battery backup and surge protection while two supply surge-only protection. The unit suits network appliances, departmental servers and office infrastructure requiring uninterruptible power in a compact rack form factor.
Line-interactive topology with automatic voltage regulation corrects brownouts and overvoltages without draining the battery. GreenPower UPS technology reduces energy consumption during normal operation. A multifunction LCD panel reports input and output voltage, load level, battery capacity, estimated runtime, AVR status and operating mode. Audible alarms signal on-battery, low-battery and overload conditions. EMI and RFI filtering suppresses line noise.
USB and serial ports enable communication with PowerPanel management software for graceful shutdown and monitoring. A combined RJ11 and RJ45 pass-through protects modem or network cables from surges. The sealed lead-acid battery pack uses replaceable RB0690X4 modules and recharges in eight hours. Runtime is eleven minutes at half load and two minutes at full load. This UPS does not suit loads exceeding 900 W or installations requiring pure sine wave output.
| Brand | CyberPower |
|---|---|
| Model | OR1500LCDRM1U |
| Input Voltage Range | 90 - 140 Vac |
| Input Frequency | 60 Hz +/- 3 Hz |
| Input Connection | NEMA 5-15P |
| VA Rating | 1500 VA |
| Watts | 900 Watts |
| Output Voltage | 120 V +/- 10% |
| Output Frequency | 60 Hz +/- 1% |
| Outlets | 4 x 5-15R Battery & Surge 2 x 5-15R Surge-Only |
| Outlet Type | NEMA 5-15R |
| Battery Type | Sealed Lead Acid |
| Battery Run Time | Runtime at Half Load: 11 minutes Runtime at Full Load: 2 minutes |
| Battery Recharge Time | 8 Hour(s) |
| Battery Replaceable | RB0690X4 |
| Alarms | On Battery, Low Battery, Overload |
| Interface Port | USB, Serial |
| Approvals | UL1778, cUL 107.1, FCC DOC Class B |
| Rackmountable | 1U |
| Data Line Protection | Phone RJ11 / Ethernet RJ45: 1-In, 1-Out (Combo) |
| Surge Energy Rating | 1,030 Joules |
| Protection | Internal Circuitry Limiting / Circuit Breaker |
| Features | Intelligent LCD Diagnostic Display: The innovative front panel LCD can be used to display detailed information on the UPS status and current power conditions. The LCD displays 11 different diagnostics: AVR Status, Estimated Runtime, Battery Capacity, Load Level, Input & Output Voltage Level, Output Frequency, On-Battery, Overload, Fault, Silent Mode, and more. Automatic Voltage Regulation (AVR) - AVR takes irregular AC power and converts it into a consistent Sinewave so sensitive electronic equipment can achieve its optimal performance. This “Boost/Buck” topology will both increase l |
| Dimensions | 17.25" x 19.50" x 1.75" |
| Weight | 45.60 lbs. |
| Fraktvekt | 22.36 kg |
| Pakkestørrelse | 610 × 549 × 150 mm |
Andre versjoner av denne modellen
Samme familie, annet minne, annen kjøler eller klokkefrekvens — sammenlign før du bestemmer deg.
Mount the unit using the included brackets, plug the NEMA 5-15P cord into a 120 V circuit, then connect critical loads to the four battery-backed outlets and non-critical loads to the two surge-only outlets; the step often missed is wiring the RJ11/RJ45 combo port for phone or Ethernet surge protection.
The sealed lead-acid batteries typically last three to five years; replace all four 6 V 9.0 Ah modules at once with part RB0690X4 and allow an eight-hour recharge before returning to full runtime.
Battery runtime drops to about two minutes at full load, so the endurance limit appears long before thermal or overload alarms activate.
Også i denne avdelingen
Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.
Det du betaler med, og det du ser prisene i.
Sendes fra lommeboken din i kassen
Kun visning — katalogen er prissatt i USD
Fant ingen valuta.
Velg språket nettstedet snakker til deg på.
Ingen språk samsvarer.
Ny her?
Har du allerede en konto?
Det finnes ingen automatisk tilbakestilling: butikken sender ikke e-post, så det finnes ingen engangslenke å be om. La adressen stå på kontoen, så blir den behandlet manuelt.
Forespørsel registrert
Ingenting er på vei til innboksen din — butikken sender ingen e-post i det hele tatt. Noen behandler dette manuelt.
Husket du det likevel?