Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.

Overvåkingsliste Logg inn

KHACHIMO

KHACHIMO MTAA-16W-A CONDOR Industrial Medical Power Supply 5V2A 6.2V 0.4A 9-15V

SKU CH-MXG3-FBQ5X

Industrial medical power module delivering 5 V at 2 A, 6.2 V at 0.4 A and 9 V to 15 V at 0.4 A with 16 W total output

  • TypeATX
  • Industrial medical grade power module
  • 16 W output capacity for demanding equipment
  • Dual 5 V 2 A and 6.2 V 0.4 A rails
  • Adjustable 9 V to 15 V auxiliary rail

Condor Medical Power Module

The KHACHIMO MTAA-16W-A is a 16 W ATX power module built for CONDOR industrial medical equipment. It delivers regulated 5 V at 2 A and 6.2 V at 0.4 A for specialised healthcare hardware. This new unit is tested working and suited for technicians maintaining compliant medical systems. It is not for builders needing standard PC ATX rails or higher wattage for graphics cards.

Thermals Noise and Power Draw

The 16 W design keeps heat output low inside enclosed medical chassis. Fanless operation eliminates audible noise in quiet clinical settings. Input voltage accepts 9 to 15 V DC, drawing 0.4 A at the top of that range. Efficiency figures are not supplied by the manufacturer.

Høydepunkter

  • Industrial medical grade power module
  • 16 W output capacity for demanding equipment
  • Dual 5 V 2 A and 6.2 V 0.4 A rails
  • Adjustable 9 V to 15 V auxiliary rail

Spesifikasjoner

TypeATX

Spørsmål om denne varen

How do I connect the MTAA-16W-A module to my system, and what wiring mistake should I avoid?

Wire the input to a 9 to 15 volt DC source observing polarity, then attach the 5 volt 2 amp and 6.2 volt 0.4 amp outputs; the common error is reversing the input polarity which can damage the unit.

What maintenance or replacement will the MTAA-16W-A need over time?

The module has no user-serviceable parts; plan to replace the entire unit if output voltages drift outside the 5 volt 2 amp or 6.2 volt 0.4 amp rails after extended operation.

Også i denne avdelingen

Kunder sammenlignet disse

Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.