MINUTEMAN RPM158N1LCD-15P PDU 8-outlet 15A 10ft cord
- Power Distribution…
- Horizontal Installa…
Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.
MINUTEMAN
An IP-addressable PDU with eight NEMA 5-15/20R outlets, a local LCD and a 10 ft NEMA 5-L20P cord
Model RPM208N1LCD-L20P
The Minuteman RPM208N1LCD-L20P is an IP-addressable power distribution unit built for server rooms and network closets that need remote control of eight NEMA 5-15/20R outlets. It mounts in 1U horizontal or 0U vertical orientation and connects via a 10 ft cord with a NEMA 5-L20P plug rated for 100-120 VAC input.
The unit carries a 20 A input breaker and a 16 A maximum continuous load rating, so all eight receptacles share that ceiling without tripping under steady demand. An integrated web server enables scheduled on/off/reset cycles for individual outlets, while SNMP traps and email alerts report overload events before they reach the breaker threshold.
A local LCD panel displays real-time amperage, internal temperature and humidity readings alongside the assigned IP address for at-a-glance rack monitoring. The built-in 10/100 Base-T Ethernet port supports IPv4, IPv6, SNMP v1/v2c/v3, SSH and RADIUS authentication for secure management traffic. Alarm notifications can trigger audible, LED, email, SNMP or syslog alerts when user-defined thresholds are crossed.
| Brand | MINUTEMAN |
|---|---|
| Model | RPM208N1LCD-L20P |
| Type | Power Distribution Units |
| Style | Horizontal Installation, 0U Vertical Installation |
| Certifications | 62368-1 Certification |
| Maximum Input Current | 20A |
| Input Connector(s) | NEMA 5-L20P |
| Cord Length | 10 ft |
| Output Connector(s) | Rear Panel Receptacles: (8) 5-15/20R |
| Maximum Output Current | 20A |
| Overload Protection | Input Circuit Breaker Protection |
| Features | IP-addressable Remote Power Manager Built-in Web Server to support Remote Power Management Event Notifications via Email or SNMP Traps Local LCD displays Amps, IP Address, Temperature and/or Humidity Daily, Weekly, Monthly & Yearly Power Consumption Data 10/100 Base-T Ethernet Port IPv4, IPv6 Support and SNMP Support (v1,v2c,v3) Telnet, SSH Encryption Support Radius Authentication User Account for Three Different Permissions Management Systems Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm SSL Web Browser for Set Up and Operation IP Address Filtering Maximum 5,000 E |
| Fraktvekt | 3.63 kg |
| Pakkestørrelse | 505 × 211 × 89 mm |
Andre versjoner av denne modellen
Samme familie, annet minne, annen kjøler eller klokkefrekvens — sammenlign før du bestemmer deg.
The local LCD shows real-time amps, temperature and humidity so you can monitor heat, and the 20-amp input breaker protects the 16-amp maximum load during all-day operation.
You need a NEMA 5-L20P 20-amp inlet on your power source and devices with NEMA 5-15 or 5-20 plugs for the eight rear receptacles.
Yes, the built-in web server supports IPv4, IPv6, SNMP v1, v2c and v3 plus Telnet and SSH, so legacy management systems can poll or receive traps from the PDU.
Også i denne avdelingen
Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.
Det du betaler med, og det du ser prisene i.
Sendes fra lommeboken din i kassen
Kun visning — katalogen er prissatt i USD
Fant ingen valuta.
Velg språket nettstedet snakker til deg på.
Ingen språk samsvarer.
Ny her?
Har du allerede en konto?
Det finnes ingen automatisk tilbakestilling: butikken sender ikke e-post, så det finnes ingen engangslenke å be om. La adressen stå på kontoen, så blir den behandlet manuelt.
Forespørsel registrert
Ingenting er på vei til innboksen din — butikken sender ingen e-post i det hele tatt. Noen behandler dette manuelt.
Husket du det likevel?