Vi tar imot kryptovaluta — slik kan kryptovalutaene du eier, kjøpe ekte maskinvare.Betal med krypto, bruk den på ekte maskinvare. Gratis, forsikret levering verden over for bestillinger over 399 $. Nøytrale kartonger uten merking, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Kursen din er låst i 30 minutter når kassen åpnes.Kurs låst i 30 minutter. Alle varer er forseglet, serienummerkontrollert og dekket av 24 måneders garanti.Forseglet, 24 måneders garanti.

Overvåkingsliste Logg inn

Tripp Lite

Tripp Lite SU750RTXLCD2U 750VA 675W 120V UPS

SKU CH-X897-M8ATP MPN SU750RTXLCD2U

Double-conversion sine-wave UPS delivers 750 VA and 675 W through eight NEMA 5-15R outlets with hot-swappable batteries and LCD monitoring

  • International Version120V
  • Input ConnectionNEMA 5-15P
  • VA Rating750 VA
  • Watts675 Watts
  • Output Voltage120V
  • Outlets8
  • Double-conversion sine wave output protects sensitive equipment
  • 750 VA 675 W capacity supports critical loads during outages
  • Hot-swappable user-replaceable batteries enable continuous operation
  • Eight NEMA 5-15R outlets connect multiple devices directly
  • LCD front panel plus USB RS-232 and SNMP slot simplify monitoring

Double-Conversion UPS for Rack or Tower Use

The Tripp Lite SMARTONLINE SU750RTXLCD2U delivers 750VA and 675W of continuous 120V sine-wave power through an on-line double-conversion topology. It accepts a NEMA 5-15P input and provides eight NEMA 5-15R outlets for connected equipment. The unit is designed for 2U rackmount or tower placement and operates in environments from 32°F to 104°F.

Hot-Swappable Battery and Flexible Mounting

Valve-regulated lead-acid batteries are user-replaceable without powering down the load, and recharge to 90 percent in three hours. At full load of 675W the system runs for 7.9 minutes, extending to 20.9 minutes at half load of 338W. An audible alarm signals startup, power failure, low battery, overload and fault conditions. Surge suppression is rated at 190 Joules.

Network Card Slot and Multiple Management Ports

A dedicated slot accepts an optional LX Platform network management card for 24/7 remote access. Built-in interfaces include USB, RS-232, contact closure and an SNMP/Web card slot, enabling automatic saves and graceful shutdowns via power management software. The front-panel LCD provides real-time status, and the unit restarts automatically when utility power returns.

Høydepunkter

  • Double-conversion sine wave output protects sensitive equipment
  • 750 VA 675 W capacity supports critical loads during outages
  • Hot-swappable user-replaceable batteries enable continuous operation
  • Eight NEMA 5-15R outlets connect multiple devices directly
  • LCD front panel plus USB RS-232 and SNMP slot simplify monitoring

Spesifikasjoner

BrandTRIPP LITE
SeriesSMARTONLINE Series
ModelSU750RTXLCD2U
International Version120V
Input ConnectionNEMA 5-15P
VA Rating750 VA
Watts675 Watts
Output Voltage120V
Outlets8
Outlet Type(8) NEMA 5-15R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull load runtime: 7.9 min. (675W)
Half load runtime: 20.9 min. (338W)
Battery Recharge Time3 hours recharge to 90%
Battery ReplaceableHot-swappable, user replaceable batteries
AlarmsAudible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Interface Port(1) Contact closure; (1) RS-232; (1) Slot for SNMP/Web interface; (1) USB
RackmountableYes
Surge Energy Rating190 Joules
TemperatureOperating Temperature Range: 32° to 104°F (0° to 40°C)
Storage Temperature Range: With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C)
Humidity0-96% non-condensing
Dimensions3.41" x 17.33" x 17.72"
Weight36.38 lbs.
Package Contents750VA 675W 120V Double-Conversion UPS
USB cable
DB9 cable
Rack-mounting hardware
Tower support stands
Safety instructions
Quick start guide
Fraktvekt19.05 kg
Pakkestørrelse600 × 505 × 225 mm

Andre versjoner av denne modellen

5 flere i samme serie

Samme familie, annet minne, annen kjøler eller klokkefrekvens — sammenlign før du bestemmer deg.

Spørsmål om denne varen

What interface ports are available on the SU750RTXLCD2U for management and monitoring?

The UPS provides one contact closure port, one RS-232 serial port, one USB port, and one expansion slot for an optional SNMP/Web network management card.

What physical space and mounting options does this 2U rack/tower UPS require?

It occupies 2U of rack height and includes hardware for both 19-inch rack mounting and tower orientation on a shelf or floor.

How do you replace the batteries without shutting down connected equipment?

The VRLA batteries are hot-swappable; slide the front panel open, disconnect the old battery pack, insert the new one, and reconnect while the UPS stays online.

Også i denne avdelingen

Kunder sammenlignet disse

Samme hylle, samme kasse — åtte mynter og 30 minutters kurslås.