SQUARE D
SQUARE D XENG1191 22 mm 10A 600V 2NO/1NC EarlyClose
A 22 mm pendent contact block rated 10 A at 600 V with 2NO/1NC early-close action for Schneider XACA stations
- Engine BrandSCHNEIDER ELECTRIC
- Engine Size22 mm
- Early-close action ensures make-before-break sequencing
- 22 mm screw-clamp terminals simplify panel wiring
- Rated 10 A at 600 V AC/DC for heavy loads
- Meets CSA 22.2 No. 14, IEC 60947-5-1 and UL 508
- 2NO/1NC contact form fits Schneider XACA pendent heads
Contact Block for Pendent Stations
This Schneider Electric XENG1191 contact block provides momentary make-before-break switching with a 2NO/1NC contact form. It is designed for 22 mm mounting in Schneider XACA and XACA9 pendent station heads, suited for industrial control panels requiring early-close action.
Switching Limits and Standards
The block carries a 10 A rating at 600 V AC/DC under NEMA designations A600 and Q600. It complies with CSA C22.2 No. 14, EN/IEC 60947-5-1 and UL 508, defining the maximum voltage, current and safety envelope for the application.
Early-Close Contact Timing
The defining specification is the early-close (make-before-break) contact sequence, which closes the normally-open circuits before opening the normally-closed circuit during actuation. This timing is essential for safety interlocks and sequenced control logic that cannot tolerate a momentary open state.
Öne çıkanlar
- Early-close action ensures make-before-break sequencing
- 22 mm screw-clamp terminals simplify panel wiring
- Rated 10 A at 600 V AC/DC for heavy loads
- Meets CSA 22.2 No. 14, IEC 60947-5-1 and UL 508
- 2NO/1NC contact form fits Schneider XACA pendent heads
Teknik özellikler
| Engine Brand | SCHNEIDER ELECTRIC |
|---|---|
| Engine Size | 22 mm |
Bu ürünle ilgili sorular
Should I choose the 2NO/1NC EarlyClose version or a different contact form for my pendent station?
Choose the 2NO/1NC EarlyClose block when you need two normally-open and one normally-closed circuit with make-before-break action on the same 22 mm mounting.
What does the 10A 600V rating mean once the block is wired into my control circuit?
The block carries up to 10 amps at 600 volts AC or DC per NEMA A600/Q600, so it handles standard industrial pilot-duty loads without derating.
Does the screw-clamp terminal accept standard ferrules and what torque should I apply?
The screw-clamp terminals accept standard ferrules; tighten to the torque specified in EN/IEC 60947-5-1 for 22 mm contact blocks.