Vertiv
Vertiv AS6A0NCUGNNXLKB 5 kVA UPS 4.5 kW 5 min runtime
Online double-conversion UPS delivers 5 kVA and 4.5 kW with five minutes full-load runtime and scales to 20 kVA N+1
- International Version208V
- Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
- Input Frequency40 Hz to 70 Hz auto-sensing
- Input Connection4-Wire (L-L-N-G)
- VA Rating5 kVA
- Watts4.5 kW
Option AS6A0NCUGNNXLKB
- Scalable to 20 kVA N+1 redundancy for growing critical loads
- Online double-conversion topology delivers continuous clean power to mission-critical equipment
- Five minutes full-load runtime plus 15 minutes at half load from VRLA batteries
- Wide 40–70 Hz auto-sensing input tolerates unstable generator or utility sources
- Rack or tower form factor with LCD status display fits diverse installation spaces
Mission-critical 5 kVA UPS
The Vertiv Liebert AS6A0NCUGNNXLKB is an online double-conversion UPS rated at 5 kVA and 4.5 kW, designed for mission-critical equipment. It accepts split-phase input voltages from 200/100 to 240/120 VAC with auto-sensing frequency between 40 Hz and 70 Hz. The unit operates in rack or tower orientation and supports scaling to 20 kVA N+1 redundancy.
Environmental sensors and monitoring
Factory-installed temperature, leak detection and humidity sensors provide continuous environmental awareness alongside the LCD status display. Hard-wired 4-wire L-L-N-G connections secure both input and output wiring for single-phase operation. User-configurable output frequency defaults to 60 Hz with 50 Hz selectable.
Five-minute full-load runtime
Valve-regulated lead-acid batteries deliver 5 minutes of runtime at full load and 15 minutes at half load. Operating temperature range spans 32°F to 104°F with humidity tolerance up to 95% non-condensing. Physical footprint measures 38" x 17" x 34" and weighs 415 lbs, requiring adequate floor or rack capacity.
Öne çıkanlar
- Scalable to 20 kVA N+1 redundancy for growing critical loads
- Online double-conversion topology delivers continuous clean power to mission-critical equipment
- Five minutes full-load runtime plus 15 minutes at half load from VRLA batteries
- Wide 40–70 Hz auto-sensing input tolerates unstable generator or utility sources
- Rack or tower form factor with LCD status display fits diverse installation spaces
Teknik özellikler
| Brand | Vertiv |
|---|---|
| Series | Liebert |
| Model | AS6A0NCUGNNXLKB |
| International Version | 208V |
| Input Voltage Range | 200/100, 208/120, 220/110, 230/115, 240/120 VAC |
| Input Frequency | 40 Hz to 70 Hz auto-sensing |
| Input Connection | 4-Wire (L-L-N-G) |
| VA Rating | 5 kVA |
| Watts | 4.5 kW |
| Output Voltage | 200/100, 208/120, 220/110, 230/115, 240/120 VAC |
| Output Frequency | 60Hz default; 50/60Hz user-configurable |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Full Load: 5 mins. Half Load: 15 mins. |
| Temperature | Operating temperature: 32°F - 104°F (0°C - 40°C) |
| Humidity | 0 - 95%, non-condensing |
| Dimensions | 38" x 17" x 34" |
| Weight | 415 lbs. |
| Kargo ağırlığı | 188.24 kg |
| Koli boyutu | 965 × 864 × 432 mm |
Bu modelin diğer sürümleri
Aynı seriden 5 tane daha
Aynı aile, farklı bellek, soğutucu veya frekans — karar vermeden önce karşılaştırın.
Vertiv AS3A0NCUGNNXLKB 5 kVA 4.5 kW 208 V 5 min runtime UPS
- 208V
- 200/208/220/230/240…
Vertiv AL5A0NHUGNNXLKB UPS 5kVA/4.5kW 208/120V 8min runtime
- 208V
- 200/100, 208/120, 2…
Vertiv Liebert AS5B0NCVGNNXLKB 10kVA Scalable to 15kVA N+1 208V Split Phase Modular UPS
- 208V
- 200/100, 208/120, 2…
Vertiv AS6B0NCVGNNXLKB 10kVA 9kW 208V Split Phase UPS 5min Runtime
- 208V
- 200/100, 208/120, 2…
Bu ürünle ilgili sorular
How often will the Valve Regulated Lead Acid batteries need replacement?
The internal VRLA cells are rated for a 5-minute full-load runtime and 15 minutes at half load; typical service life is three to five years before capacity drops below useful levels.
What limits continuous output before the unit derates or shuts down?
The 4.5 kW rating is the sustained ceiling; exceeding it triggers immediate overload protection, and the 40 °C maximum operating temperature is the thermal limit that forces derating if airflow is restricted.
How much heat and fan noise should I expect when this UPS runs 24/7 at full load?
At 4.5 kW the double-conversion modules dissipate roughly 15 % of rated power as heat, and the internal fans ramp to maintain the 40 °C internal limit, producing noticeable but data-centre-typical airflow noise.
Bu reyondan diğerleri
Müşteriler bunları karşılaştırdı
Aynı raf, aynı sipariş tamamlama — sekiz koin ve 30 dakikalık kur kilidi.
Black Box Corporation DisplayPort to DVI Fibre Optic Cable 15 ft 4.5 m 1.35 GB/s
- Consumer Electronics