Vertiv Liebert AS5A0NCUGNNXLKB 5 kVA UPS
- 208V
- 200/100, 208/120, 2…
Vertiv
Online double-conversion UPS delivers 5 kVA and 4.5 kW with five minutes full-load runtime and scales to 20 kVA N+1
Option AS6A0NCUGNNXLKB
The Vertiv Liebert AS6A0NCUGNNXLKB is an online double-conversion UPS rated at 5 kVA and 4.5 kW, designed for mission-critical equipment. It accepts split-phase input voltages from 200/100 to 240/120 VAC with auto-sensing frequency between 40 Hz and 70 Hz. The unit operates in rack or tower orientation and supports scaling to 20 kVA N+1 redundancy.
Factory-installed temperature, leak detection and humidity sensors provide continuous environmental awareness alongside the LCD status display. Hard-wired 4-wire L-L-N-G connections secure both input and output wiring for single-phase operation. User-configurable output frequency defaults to 60 Hz with 50 Hz selectable.
Valve-regulated lead-acid batteries deliver 5 minutes of runtime at full load and 15 minutes at half load. Operating temperature range spans 32°F to 104°F with humidity tolerance up to 95% non-condensing. Physical footprint measures 38" x 17" x 34" and weighs 415 lbs, requiring adequate floor or rack capacity.
| Brand | Vertiv |
|---|---|
| Series | Liebert |
| Model | AS6A0NCUGNNXLKB |
| International Version | 208V |
| Input Voltage Range | 200/100, 208/120, 220/110, 230/115, 240/120 VAC |
| Input Frequency | 40 Hz to 70 Hz auto-sensing |
| Input Connection | 4-Wire (L-L-N-G) |
| VA Rating | 5 kVA |
| Watts | 4.5 kW |
| Output Voltage | 200/100, 208/120, 220/110, 230/115, 240/120 VAC |
| Output Frequency | 60Hz default; 50/60Hz user-configurable |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| Battery Run Time | Full Load: 5 mins. Half Load: 15 mins. |
| Temperature | Operating temperature: 32°F - 104°F (0°C - 40°C) |
| Humidity | 0 - 95%, non-condensing |
| Dimensions | 38" x 17" x 34" |
| Weight | 415 lbs. |
| 배송 무게 | 188.24 kg |
| 포장 크기 | 965 × 864 × 432 mm |
이 모델의 다른 버전
같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.
The internal VRLA cells are rated for a 5-minute full-load runtime and 15 minutes at half load; typical service life is three to five years before capacity drops below useful levels.
The 4.5 kW rating is the sustained ceiling; exceeding it triggers immediate overload protection, and the 40 °C maximum operating temperature is the thermal limit that forces derating if airflow is restricted.
At 4.5 kW the double-conversion modules dissipate roughly 15 % of rated power as heat, and the internal fans ramp to maintain the 40 °C internal limit, producing noticeable but data-centre-typical airflow noise.
이 진열대의 다른 상품
같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.
결제할 코인과 가격을 확인할 통화입니다.
체크아웃 시 지갑에서 전송됩니다.
표시 전용 — 카탈로그 가격은 달러 기준입니다.
일치하는 통화가 없습니다.
사이트에서 사용할 언어를 선택하십시오.
일치하는 언어가 없습니다.
처음 방문하셨나요?
이미 계정이 있으신가요?
자동 재설정 기능은 없습니다. 이 쇼핑몰은 어떠한 메일도 보내지 않으므로 요청할 일회용 링크 자체가 없습니다. 계정에 등록된 이메일 주소를 그대로 두시면 담당자가 직접 확인해 처리합니다.
요청 접수
받은편지함으로 오는 것은 아무것도 없습니다 — 이 쇼핑몰은 메일을 전혀 보내지 않습니다. 담당자가 직접 확인해 처리합니다.
기억나셨나요?