Scalable 10 kVA online double-conversion UPS with 5 minutes full-load runtime and factory-installed SNMP card

  • International Version208V
  • Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
  • Input Frequency40 Hz to 70 Hz auto-sensing
  • Input Connection4-Wire (L-L-N-G)
  • VA Rating10 kVA
  • Watts9 kW
  • Scalable to 20kVA N+1 redundancy for growing power needs
  • Online double-conversion topology delivers clean 9kW output
  • Factory-installed SNMP webcard enables remote monitoring
  • 5 minutes full-load runtime with VRLA batteries
  • Rack or tower form factor fits diverse installations

10 kVA Split-Phase UPS for Critical Loads

This Vertiv Liebert unit delivers 10 kVA and 9 kW of online double-conversion power with a 208 V split-phase output. It is built for data-centre racks or tower deployments that need continuous clean power for servers, storage arrays and network gear. The system scales to 20 kVA in an N+1 redundant frame, so growing infrastructure can add capacity without replacing the chassis. Buyers who only need single-phase output or runtime beyond 5 minutes at full load should look elsewhere.

Rack-or-Tower Installation with Factory SNMP Card

The chassis measures 38 by 17 by 34 inches and weighs 510 lbs, so it requires a rated rack or solid floor space and mechanical assistance to position. Input uses a four-wire L-L-N-G connection across 200 to 240 V line-to-line voltages, and the 40–70 Hz auto-sensing input tolerates unstable grids. The SNMP/Webcard is already fitted, removing a common integration step. Installers must still provide external battery modules for extended runtime, and the 49-inch overall height may exceed standard 42 U rack clearance.

Five-Minute Full-Load Runtime Defines Sizing

At 100 percent load the VRLA battery set sustains output for 5 minutes; at half load the runtime extends to 15 minutes. This figure is the primary constraint for right-sizing the UPS to the protected equipment. If the connected load cannot be shed to half within that window, or if a longer bridge to generator start is required, additional battery cabinets must be specified. The operating range of 32–104 °F and 0–95 percent non-condensing humidity must also match the site environment.

주요 특징

  • Scalable to 20kVA N+1 redundancy for growing power needs
  • Online double-conversion topology delivers clean 9kW output
  • Factory-installed SNMP webcard enables remote monitoring
  • 5 minutes full-load runtime with VRLA batteries
  • Rack or tower form factor fits diverse installations

사양

BrandVertiv
SeriesLiebert
ModelAS6B0NCVGNNXLKB
International Version208V
Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
Input Frequency40 Hz to 70 Hz auto-sensing
Input Connection4-Wire (L-L-N-G)
VA Rating10 kVA
Watts9 kW
Output Voltage200/100, 208/120, 220/110, 230/115, 240/120 VAC
Output Frequency60Hz default; 50/60Hz user-configurable
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load: 5 mins.
Half Load: 15 mins.
TemperatureOperating temperature: 32°F - 104°F (0°C - 40°C)
Humidity0 - 95%, non-condensing
Dimensions38" x 17" x 34"
Weight510 lbs.
배송 무게231.33 kg
포장 크기965 × 864 × 432 mm

이 모델의 다른 버전

같은 라인업에서 5개 더

같은 제품군에서 메모리·쿨러·클럭이 다릅니다 — 결정 전에 비교해 보세요.

이 상품에 대한 질문

How can I confirm the UPS is operating correctly after installation?

The front LCD status indicators display real-time input voltage, output voltage, load percentage, battery charge level and any active alarms so you can verify normal operation at a glance.

What ships with the unit and what must be purchased separately?

The UPS module arrives with the factory-installed SNMP/Webcard and internal VRLA battery strings; external battery cabinets, rail kits and PDU accessories are sold separately.

Which capacity should I choose if I need to scale beyond 10 kVA?

This frame scales to 20 kVA in an N+1 redundant configuration by adding a second power module within the same 38 x 17 x 34 inch rack/tower enclosure.

이 진열대의 다른 상품

고객들이 함께 비교한 상품

같은 진열대, 같은 체크아웃 — 코인 8종, 환율 잠금 30분.