Tycon Systems TP-VRHP-2456 DC Voltage Converter 18-36V 56V 1.25A 70W
- Tycon Systems
Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.
Analog Technologies, Inc.
A linear DC-DC high-voltage module converts 12 V input to an adjustable 0 to -1 kV output at up to 20 mA for industrial and scientific equipment
The AHV12V1KV20MAW converts a 12 V supply into a tightly regulated 0 to -1 kV output with a maximum current of 20 mA. It is built for engineers integrating high-voltage rails into X‑ray, spectroscopy, semiconductor or particle‑accelerator systems where stability and low EMI are mandatory.
Legacy rack‑mount units often demand forced‑air cooling and generate audible hum; this metal‑enclosed module delivers comparable regulation with zero EMI and passive heat sinking. The jump is worth it when a test bench or production tool needs a silent, vibration‑free source that fits inside an existing chassis without redesign.
A single 12 V rail rated for 550 mA to 2.4 A feeds the module, while a 0 to 5 V control signal sets the output voltage proportionally. The onboard 5 V reference (±0.05 V) simplifies closed‑loop designs, and electronic shutdown lets the host controller cut power instantly. No extra cooling hardware or isolation transformers are required, leaving more room for the application itself.
| Type | Linear Power Supplies |
|---|---|
| Voltage | 500V |
| Amps | 10mA |
The module accepts 12V ± 1V input with a current draw between 550mA and 2.4A depending on load conditions.
Output voltage is set by applying a 0 to 5V control signal to the CTRL pin; 0V gives 0V output and 5V gives -1kV output.
The sealed metal enclosure provides zero EMI and heat sinking; no internal maintenance is required, only verify external airflow remains unobstructed.
Også på denne hylde
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Det du betaler med, og det du ser priserne i.
Sendes fra din tegnebog i kassen
Kun til visning — kataloget er prissat i USD
Ingen valuta matcher det.
Vælg det sprog, siden taler til dig på.
Ingen sprog matcher.
Ny her?
Har du allerede en?
Der findes ingen automatisk nulstilling: denne butik sender ingen e-mails, så der er intet engangslink at bede om. Efterlad adressen på kontoen, så bliver den behandlet manuelt.
Anmodning registreret
Der er intet på vej til din indbakke — denne butik sender slet ingen e-mails. Nogen behandler dem manuelt.
Kom du i tanke om den?