APC
APC AP7921B Switched 1U PDU 20A 8.2ft 8×C13 3680VA
Switched 1U rack PDU with eight C13 outlets, 20 A input, 8.2 ft cord and remote outlet control
- TypeSwitched
- Rack Size1U
- CertificationscUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-
- ROHSYes
- Input Voltage200V, 208V, 230V
- Input Frequency50/60 Hz
- Switched outlets enable remote power cycling per device
- 1U rack height fits standard server cabinets
- 2 ft input cord reaches distant power sources
- 8×C13 outputs support multiple servers or switches
- Local current display warns of overload instantly
Switched 1U PDU with Eight C13 Outlets
This APC AP7921B is a switched rack power distribution unit that occupies one rack unit and provides eight IEC 320 C13 outlets. It accepts 200V to 230V input through an IEC-320 C20 plug on an 8.2 ft cord and delivers up to 3680 VA. Remote outlet switching and a local current display let administrators manage loads from anywhere.
Suits Managed Racks; Not for Unmetered Basic Power
Network managers who need per-outlet control, multi-tier user access and real-time load monitoring will use the switched features daily. The unit also carries cUL, CE, CSA and VDE certifications for regulated environments. Builders who only need simple power distribution without remote switching or a current display should consider a basic PDU instead.
20 A Maximum Input with 16 A Derated Limit
The PDU is rated for a maximum input current of 20 A, but regulatory derating restricts continuous draw to 16 A. This 4 A gap determines how many devices you can safely connect on a single branch circuit. Exceeding the derated value risks tripping upstream protection even though the hardware tolerates the higher peak.
Fordele
- Switched outlets enable remote power cycling per device
- 1U rack height fits standard server cabinets
- 2 ft input cord reaches distant power sources
- 8×C13 outputs support multiple servers or switches
- Local current display warns of overload instantly
Specifikationer
| Brand | APC |
|---|---|
| Model | AP7921B |
| Type | Switched |
| Rack Size | 1U |
| Certifications | cUL Listed, CE, CSA, EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, UL 60950, UL Listed, VDE, VCCI |
| ROHS | Yes |
| Input Voltage | 200V, 208V, 230V |
| Input Frequency | 50/60 Hz |
| Maximum Input Current | 20A |
| Regulatory Derated Input Current | 16A |
| Input Connector(s) | IEC-320 C20 |
| Cord Length | 8.2 ft |
| Output Voltage | 208V, 230V |
| Output Watts (VA) | 3680 VA |
| Output Connector(s) | (8) IEC 320 C13 (Battery Backup) |
| Operating Environment | 0 - 45 degree Celsius |
| Operating Relative Humidity | 0 - 95% |
| Operating Elevation | 0 - 3000 m |
| Storage Temperature | -25 - 65 ºC |
| Storage Relative Humidity | 0 - 95% |
| Storage Elevation | 0 - 15000 m |
| Dimensions | 1.73" x 17.50" x 4.25" |
| Weight | 5.00 lbs. |
| Forsendelsesvægt | 3.87 kg |
| Pakkestørrelse | 559 × 375 × 160 mm |
Spørgsmål om denne vare
What rack height does the 1U switched PDU occupy and what input plug does it use?
The unit fits a standard 1U rack space and connects via an IEC-320 C20 inlet on an 8.2 ft cord.
How is the PDU mounted and which step is often missed during setup?
It mounts horizontally using the supplied rack brackets; the step often missed is securing the cord retention bracket to prevent the C20 plug from pulling loose.
What environmental limits should be monitored for long-term operation?
Operate between 0 and 45 °C with humidity up to 95 % non-condensing; storage allows -25 to 65 °C and the same humidity range.
Også på denne hylde
Kunderne har også sammenlignet disse
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
Thermal Grizzly TG-MP8-120-20-30-1R Minus Pad 8 chipset cooling 120x20x3.0mm
DOCTOR METAL 3x 120mm case fan pack white with controller
- Case Fan
- Case
DOCTOR METAL 120 mm case fan 3-pack with controller
- Case Fan
- Case