Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.

Prisvagt Log ind

CyberPower

CyberPower PDU41001G 1U Switched PDU 8x5-15R 120V 15A 12ft

SKU CH-VB2J-RYJ27 MPN PDU41001G

A 1U switched power distribution unit with eight NEMA 5-15R outlets, dual gigabit Ethernet ports and a 12 ft input cord for 120V 15A service

  • TypeSwitched
  • Rack Size1U
  • StyleHorizontal/Rackmount/Wallmount
  • Front Panel LEDsTx/Rx LINK Normal/Warning/Critical Status
  • CertificationsEnvironmental: RoHS Compliant Safety: UL62368 FCC Class A IC
  • Input Voltage120V
  • Remote power control via dual gigabit Ethernet and SNMP
  • Automated alerts by email, SMS and SNMP trap
  • Eight NEMA 5-15R outlets on a 1U horizontal chassis
  • 12 ft input cord with NEMA 5-15P plug for flexible placement
  • UL 62368 safety certification and RoHS compliance

Switched PDU with 8 NEMA 5-15R Outlets

This 1U rack-mountable power distribution unit provides eight switched NEMA 5-15R outlets fed by a 12 ft cord with a NEMA 5-15P plug. It operates on single-phase 120 V input at 50/60 Hz with a 15 A circuit breaker and a regulatory derated current of 12 A. Dual Gigabit Ethernet ports enable SNMP management and automated email, SMS, or SNMP trap notifications.

Suited for 120 V Racks Needing Remote Outlet Control

Network administrators can power-cycle individual outlets and monitor status via the front-panel Tx/Rx LEDs or the management interface. The unit is not suited for installations that require 20 A or higher input circuits, nor for environments needing outlet-level power metering or vertical 0U mounting.

Single-Phase 120 V Input at 15 A with 12 A Derating

The regulatory derated input current of 12 A is the limiting specification for continuous load planning. Exceeding this value will trip the 15 A breaker, so total connected equipment must stay within the derated limit.

Fordele

  • Remote power control via dual gigabit Ethernet and SNMP
  • Automated alerts by email, SMS and SNMP trap
  • Eight NEMA 5-15R outlets on a 1U horizontal chassis
  • 12 ft input cord with NEMA 5-15P plug for flexible placement
  • UL 62368 safety certification and RoHS compliance

Specifikationer

BrandCyberPower
ModelPDU41001G
TypeSwitched
Rack Size1U
StyleHorizontal/Rackmount/Wallmount
Front Panel LEDsTx/Rx
LINK
Normal/Warning/Critical Status
CertificationsEnvironmental:
RoHS Compliant
Safety:
UL62368
FCC Class A
ICES-003: Issue 7
Input Voltage120V
Input Frequency50/60 Hz
Maximum Input Current15A
Regulatory Derated Input Current12A
Input Connector(s)Input Plug Type: NEMA 5-15P
Cord Length12 ft
Output Connector(s)Outlet Type: 8 - NEMA 5-15R
Outlets - Front: 8
Outlets - Rear: 0
Outlets - Total: 8
Overload Protection15A
Operating Environment32 - 140 °F (0 - 60 °C)
Operating Relative Humidity0 - 95 % (non-condensing)
Operating Elevation0 - 11483 ft (0 - 3500 m)
Storage Temperature5 - 149 °F (-15 - 65 °C)
Storage Elevation0 - 49213 ft (0 - 14999 m)
Dimensions1.75'' x 17.05'' x 4.41''
Weight5.7 lbs.
Forsendelsesvægt3.54 kg
Pakkestørrelse495 × 248 × 64 mm

Spørgsmål om denne vare

How do I mount the 1U PDU in a rack and connect the 12 ft NEMA 5-15P cord without blocking airflow?

Use the included brackets for horizontal 1U rackmount or wallmount; route the 12 ft cord to the 120 V 15 A NEMA 5-15P receptacle, leaving clearance around the 1.75 in tall chassis for the 0–60 °C operating range.

What ongoing maintenance does the switched PDU with dual Gigabit Ethernet ports require?

Keep the Tx/Rx LEDs visible for link status, ensure vents stay clear within the 0–95 % non-condensing humidity limit, and verify SNMP trap and email alerts remain configured for overload notification.

At what sustained load does the 15 A overload protection trip, given the 12 A derated input rating?

The regulatory derated input current is 12 A; continuous draw above 12 A on the 120 V single-phase feed will trigger the 15 A breaker on the eight NEMA 5-15R outlets.