Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.

Prisvagt Log ind

CyberPower

CyberPower PR2200ELCDRTXL2U 2200 VA 1650 W 2U Rackmount UPS

SKU CH-8734-5QS5Z MPN PR2200ELCDRTXL2U

A 2U rackmount UPS delivering 2200 VA and 1650 W with ten IEC outlets and a four-millisecond transfer time

  • Input Voltage RangeInput Voltage Range: 160 - 288 VAC Adjustable Voltage Range:
  • Input Frequency50/60Hz +/- 0.1Hz
  • Input ConnectionIEC320 C20
  • VA Rating2200 VA
  • Watts1650 W
  • Output Voltage220 / 230 / 240 VAC +/- 5%

Options PR2200ELCDRTXL2U

  • 2200 VA 1650 W protects critical rack equipment
  • Pure sinewave output keeps sensitive servers running cleanly
  • 10 IEC outlets including C19 and C13 connect diverse gear
  • USB serial EPO ports enable automated management
  • 2U rackmount form factor fits standard cabinets efficiently

2U Rackmount UPS with Sinewave Output

The CyberPower PR2200ELCDRTXL2U is a 2U rackmount uninterruptible power supply rated at 2200 VA and 1650 W. It delivers pure sinewave output at 220, 230 or 240 VAC with a transfer time of 4 ms. Ten IEC outlets include one C19 and nine C13 receptacles. Management is provided through USB, serial and EPO ports with PowerPanel Business Edition software.

Suited for Critical Servers and Network Gear

This unit fits administrators who need clean sinewave power for sensitive rack equipment and want remote monitoring via standard network management tools. The 2U form factor suits standard racks and the replaceable battery cartridge extends service life. Buyers who need longer runtime at full load or who require a different outlet mix should look at other models.

1650 W Power Rating Decides the Load

The 1650 W rating is the single figure that determines whether this UPS can support your connected gear. Add the power draw of every device you intend to protect; if the total exceeds 1650 W the unit will overload. The half-load runtime of 14 minutes and full-load runtime of 5 minutes follow directly from this rating.

Fordele

  • 2200 VA 1650 W protects critical rack equipment
  • Pure sinewave output keeps sensitive servers running cleanly
  • 10 IEC outlets including C19 and C13 connect diverse gear
  • USB serial EPO ports enable automated management
  • 2U rackmount form factor fits standard cabinets efficiently

Specifikationer

BrandCyberPower
SeriesSmart App Sinewave
ModelPR2200ELCDRTXL2U
Input Voltage RangeInput Voltage Range: 160 - 288 VAC
Adjustable Voltage Range: 150 - 300 VAC
Input Frequency50/60Hz +/- 0.1Hz
Input ConnectionIEC320 C20
VA Rating2200 VA
Watts1650 W
Output Voltage220 / 230 / 240 VAC +/- 5%
Output Frequency50/60 Hz +/- 0.1%
Outlets10
Outlet Type1 x IEC320 C19, 1 x IEC320 C13
Battery Run TimeRuntime at Half Load: 14 Minutes
Runtime at Full Load: 5 Minutes
Battery Recharge Time6 Hour(s)
Battery ReplaceableRBP0040
AlarmsOn Battery
Low Battery
Overload
Interface PortUSB, Serial, EPO
Management SoftwarePowerPanel Business Edition
ApprovalsCE
Rackmountable2U
Surge Energy Rating810 joules
ProtectionInternal Circuitry Limiting
Circuit Breaker
FeaturesA high-voltage rack/tower convertible UPS with line interactive topology and an adjustable output of either 220, 230 or 240 VAC, the CyberPower Smart App Sinewave PR2200ELCDRTXL2U provides battery backup, power protection (using sine wave output), and surge protection for corporate servers, department servers, storage appliances, network devices, and telecom installations requiring Active PFC power source compatibility. The PR2200ELCDRTXL2U uses Automatic Voltage Regulation (AVR) to correct minor power fluctuations without switching to battery power, which extends battery life. AVR i
Dimensions3.46" x 17.05" x 18.90"
Weight77.00 lbs.
Forsendelsesvægt42.18 kg
Pakkestørrelse610 × 559 × 267 mm

Andre versioner af denne model

4 flere i samme serie

Samme familie, men med anden hukommelse, køler eller clockfrekvens — sammenlign, før du bestemmer dig.

Spørgsmål om denne vare

How do I install the PR2200ELCDRTXL2U in a 2U rack, and which mounting step is often missed?

Mount the 3.5-inch high, 17.1-inch wide unit using the included 2U brackets; the step often missed is securing the rear support brackets to the rack's back rails to carry the 77 lb weight.

Which battery pack replaces the internal cells when runtime drops below the 14-minute half-load figure?

Order the RBP0040 replacement cartridge; it is user-replaceable and restores the original 5-minute full-load and 14-minute half-load runtimes after the typical 6-hour recharge.

At what load does the 4 ms transfer time become the limiting factor during sustained operation?

The 4 ms transfer time is fixed and does not vary with load; the first sustained-use limit is the 1650 W / 2200 VA rating — exceeding it triggers the overload alarm and forces the UPS to bypass.

Også på denne hylde

Kunderne har også sammenlignet disse

Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.