Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.

Prisvagt Log ind

CyberPower

CyberPower SL950U UPS 950VA/510W 8 Outlets USB-A/C

SKU CH-PMG8-WE9F4 MPN SL950U

Standby UPS delivers 950 VA and 510 W backup through eight NEMA 5-15R outlets plus USB-A and USB-C charging ports with 20 W shared output

  • International Version120 VAC
  • Input Frequency47 Hz - 53 Hz 57 Hz - 63 Hz
  • Input ConnectionNEMA 5-15P
  • VA Rating950 VA
  • Watts510 Watts
  • Output Voltage120V
  • 950 VA standby UPS keeps computers running during outages
  • 510 W output supports desktop PCs and networking gear
  • 890 joule surge rating protects against lightning-induced spikes
  • USB-A and USB-C ports deliver 20 W charging even on battery
  • Keyhole slots and slim profile allow discreet wall mounting

Desktop UPS for computers and networking

The CyberPower SL950U is a standby UPS rated at 950 VA and 510 W with eight NEMA 5-15R outlets. It supplies battery backup and 890 Joules of surge protection for desktop PCs, gaming consoles and home networking gear. Two USB charge ports share 20 W output and stay active during outages. The slim profile includes keyhole slots for wall mounting.

Replacing basic surge strips

A simple power strip only clamps surges; this unit adds battery runtime so a utility failure does not cut power instantly. The step up is worth it when a sudden loss would corrupt an operating system, drop a raid array or interrupt a firmware update. Automatic voltage regulation is not included, so sites with chronic brownouts need a line-interactive model instead.

Runtime and load headroom

At half load the battery lasts about 8 minutes, enough for a controlled shutdown of a typical workstation and router. At full 510 W load the reserve drops to roughly 1 minute, leaving only seconds to trigger shutdown software. The sealed lead-acid pack is not user-replaceable and requires 8 hours to recharge after a discharge event.

Fordele

  • 950 VA standby UPS keeps computers running during outages
  • 510 W output supports desktop PCs and networking gear
  • 890 joule surge rating protects against lightning-induced spikes
  • USB-A and USB-C ports deliver 20 W charging even on battery
  • Keyhole slots and slim profile allow discreet wall mounting

Specifikationer

BrandCyberPower
ModelSL950U
International Version120 VAC
Input Frequency47 Hz - 53 Hz
57 Hz - 63 Hz
Input ConnectionNEMA 5-15P
VA Rating950 VA
Watts510 Watts
Output Voltage120V
Output Frequency50/60 Hz +/- 1% (auto-sensing)
Outlets8
Outlet Type8 x NEMA 5-15R
Battery TypeSealed Lead Acid
Battery Run Time1 min Runtime at Full Load / 8 min Runtime at Half Load
Battery Recharge Time8 Hours
Battery ReplaceableNo
AlarmsBattery Mode
Low Battery
Overload
Fault
Interface Port1 x USB Type A
1 x USB Type C
ApprovalsUL1778
cUL
FCC DOC Class B
CEC
Surge Energy Rating890 Joules
ProtectionInternal Circuitry Limiting
Circuit Breaker Protected
TemperatureOperating Temperature: 32 - 104 °F (0 - 40 °C)
Storage Temperature: 5 - 113 °F (-15 - 45 °C)
HumidityOperating Relative Humidity: 0 - 95 % (non-condensing)
Storage Relative Humidity: 0 - 95% (non-condensing)
Dimensions5.4" x 12.76" x 2.76"
Weight7.05 lbs.
Forsendelsesvægt4.08 kg
Pakkestørrelse356 × 178 × 152 mm

Spørgsmål om denne vare

What are the keyhole mounting slots for on the SL950U?

The keyhole mounting slots let you hang the slim-profile UPS on a wall for discrete installation.

How do I connect the SL950U to a computer for shutdown software, and what step is often missed?

Use the USB Type-A or USB Type-C port to link the UPS to your PC, then install the management software so the system can trigger a graceful shutdown during an outage.

When will the sealed lead-acid battery inside the SL950U need replacement?

The battery is not user-replaceable; after its service life the entire UPS unit must be replaced.