DELL
DELL PowerEdge R540 2U 8 Bay 3.5" 2x Xeon Gold 5118 2.3GHz 12 Core 128GB DDR4 HBA330
A 2U rack server with dual 12-core Xeon Gold 5118 CPUs, 128GB DDR4 ECC memory, eight 3.5-inch drive bays, HBA330 controller, dual 750W PSUs and iDRAC9 Enterprise
- TypeRack
- Rack Height2U
- Redundant Hot-swap PowerYes
- CPU TypeIntel Xeon
- CPU Speed2.30 GHz
- CPU SocketLGA 3647
- Dual Xeon Gold 5118 CPUs deliver 2.3 GHz base and 3.2 GHz turbo for compute power
- 128 GB DDR4 2666 MHz ECC memory supports large virtualisation workloads
- HBA330 controller enables 12 Gb/s SAS and SATA pass-through connectivity
- Eight 3.5" drive bays with hot-swap trays provide flexible storage capacity
- iDRAC9 Enterprise gives full remote management and monitoring control
Dell PowerEdge R540 2U Server
The Dell PowerEdge R540 is a 2U rack server system built for virtualization, database hosting and file or application workloads. It ships with dual Intel Xeon Gold 5118 processors, 128GB of DDR4 ECC memory and a PERC HBA330 storage controller.
Fits data centres needing dual-socket density in 2U
This unit suits teams that want redundant 750W power supplies, eight 3.5-inch drive bays and iDRAC9 Enterprise remote management out of the box. Buyers who need installed drives, an operating system or a RAID-capable controller should look at something else.
12-core Xeon Gold 5118 at 2.3 GHz decides fit
The processor runs at a 2.3 GHz base frequency with a 3.2 GHz turbo boost across 12 cores per socket. If your workloads require higher single-thread speeds or more than the installed 128GB DDR4 capacity, this server will not match the requirement.
Fordele
- Dual Xeon Gold 5118 CPUs deliver 2.3 GHz base and 3.2 GHz turbo for compute power
- 128 GB DDR4 2666 MHz ECC memory supports large virtualisation workloads
- HBA330 controller enables 12 Gb/s SAS and SATA pass-through connectivity
- Eight 3.5" drive bays with hot-swap trays provide flexible storage capacity
- iDRAC9 Enterprise gives full remote management and monitoring control
Specifikationer
| Brand | DELL |
|---|---|
| Series | PowerEdge |
| Model | R540 |
| Type | Rack |
| Rack Height | 2U |
| Redundant Hot-swap Power | Yes |
| CPU Type | Intel Xeon |
| CPU Speed | 2.30 GHz |
| CPU Socket | LGA 3647 |
| Number of CPU Cores | 12-Core Processor |
| CPU Features | Gold 5118 |
| # of Processors Installed | 2 |
| MAX Processors | 2 |
| Installed Memory Size | 128GB |
| Memory Type | DDR4 |
| Max Memory Capacity | 1TB |
| Number of Memory Slots | 16 |
| Hard Drive (Installed) | None |
| Storage Controller | Dell Perc HBA330 Controller |
| HDD Interface | SATA/SAS |
| SSD (Installed) | No |
| Raid Level | None |
| Ethernet Controller | 1x Dell EMC Integrated Dual Port Network Daughter Card - 2x 1 Gigabit RJ45 Ports, |
| Remote Management | Dell EMC 14G PowerEdge iDRAC 9 Enterprise License |
| LAN Ports | 2 x Ports |
| Management Port | RJ 45 |
| Operating System | No |
Spørgsmål om denne vare
How do I install the Dell PERC HBA330 controller and what step is often missed?
Seat the HBA330 in the dedicated internal PCIe slot, connect the SAS cables to the 8x 3.5" backplane, then enable the controller in the BIOS before the OS sees any drives.
Which components will need replacement first during the server's life?
The two 750W hot-swap power supplies and system fans are the primary field-replaceable units; memory and CPUs are not hot-swap and require full shutdown.
What thermal or power limit appears first under sustained full load?
The dual 750W Platinum PSUs set the power ceiling; if combined CPU and memory draw exceeds the available budget the system will throttle before temperatures peak.
Også på denne hylde
Kunderne har også sammenlignet disse
Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.
DELL J1-7490AA01 All-in-One PC Core i7-10700 2.9GHz 16GB 512GB SSD 23.8" FHD
- All-in-One PC
- All-in-One
HP J1-800G6AA01 All-in-One PC Core i5-10500 16GB DDR4 512GB NVMe 23.8
- All-in-One PC
- All-in-One



