HPE
HPE JL085A Aruba X371 250W server power supply
A 250 W redundant power module with 120/230 V AC input for compatible Aruba switches
- TypeRedundant Power Supply
- Maximum Power250 W
- Input Voltage120 V AC 230 V AC
- ModularYes
- Energy-EfficientREACH
- Weight3.75
- 250 W maximum power for reliable server operation
- Hot-swappable modular design enables replacement without downtime
- Universal 100-240 V AC input works worldwide
- Compact 1.6 × 3.3 × 8.9 in form factor fits dense racks
- REACH energy-efficient compliance reduces operating costs
What this power module delivers
The HPE Aruba X371 is a redundant 250 W power supply built for compatible Aruba network switches. It accepts 120 V AC or 230 V AC input and provides 12 V DC output. The modular design allows hot-swap replacement without shutting down the chassis. It is suited for administrators maintaining high-availability campus or branch deployments.
Redundancy and efficiency details
Hot-swap capability means a failed unit can be exchanged while the switch remains powered by its partner supply. The module meets REACH energy-efficiency requirements. Its compact 1.6 by 3.3 by 8.9 inch form factor fits the designated power bay. No additional cables or software licences are included in the package.
Compatibility checks before purchase
Verify that your switch model lists the JL085A as a supported power module in its hardware guide. Confirm the chassis has an available redundant power-supply bay and that the total load stays within the 250 W rating. Ensure the site provides either 120 V AC or 230 V AC service matching the unit’s input range.
Fordele
- 250 W maximum power for reliable server operation
- Hot-swappable modular design enables replacement without downtime
- Universal 100-240 V AC input works worldwide
- Compact 1.6 × 3.3 × 8.9 in form factor fits dense racks
- REACH energy-efficient compliance reduces operating costs
Specifikationer
| Brand | HPE |
|---|---|
| Model | JL085A |
| Type | Redundant Power Supply |
| Maximum Power | 250 W |
| Input Voltage | 120 V AC 230 V AC |
| Modular | Yes |
| Energy-Efficient | REACH |
| Weight | 3.75 |
| Forsendelsesvægt | 4.54 kg |
| Pakkestørrelse | 349 × 178 × 178 mm |
Spørgsmål om denne vare
How often does the internal fan need cleaning or replacement in the JL085A 250 W unit?
The JL085A is a sealed redundant module with no user-serviceable fan; HPE does not publish a cleaning interval, so plan replacement only if the unit reports a fan fault.
What thermal limit throttles the JL085A first during continuous 250 W output?
The supply will hit its internal over-temperature protection before the 250 W rating is exceeded, shutting down to protect components.
How much heat and noise does the JL085A produce when running at full load all day?
At 250 W output the unit exhausts roughly 85 W of waste heat; fan speed ramps with temperature, so acoustic output rises under sustained load.