Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.

Prisvagt Log ind

Tripp Lite

Tripp Lite EVMAL620A PDU 24-Outlet 16A 12×C13 12×C39 L6-20P 10ft 0U

SKU CH-YVXE-DP424 MPN EVMAL620A

A managed 0U rack PDU delivering 3.8 kW through 24 outlets — twelve C13 and twelve C39 — with a 10 ft L6-20P cord, gigabit Ethernet monitoring, and support for optional environmental sensors

  • TypePDUs & Line Conditioners
  • Rack Size0U
  • Input Voltage120 V AC 230 V AC
  • Maximum Input Current16 A
  • Cord Length10 ft. Cord
  • Output Connector(s)12 x IEC 60320 C13 12 x IEC 60320 C39
  • 24 outlets in a 0U vertical form factor maximise rack density
  • 12 C13 and 12 C39 connectors support mixed IEC device loads
  • 16 A input at 120 V or 230 V delivers up to 3.8 kW
  • Embedded hot-swappable gigabit network module enables remote management and zero-trust security
  • Chain-of-trust encryption with secure firmware boot protects the PDU from network cyberattacks

Managed 0U PDU for 42U racks

The EVMAL620A is a managed vertical power distribution unit designed for enterprise data centres and colocation facilities. It fits a 42U rack without consuming horizontal space and provides 24 locking outlets for dense server deployments. IT teams gain remote monitoring and control through an embedded gigabit network module with secure firmware boot. The unit supports Eaton Brightlayer software for automation and alerting.

16 A input limits total load to 3.8 kW

The NEMA L6-20P plug feeds a maximum of 16 A across 120 V AC or 230 V AC inputs, capping continuous power at 3.8 kW. Twelve IEC 60320 C13 and twelve IEC 60320 C39 outlets share this budget, so combined device draw must stay within the rated current. The 10 ft cord connects to a compatible branch circuit; the PDU does not increase available amperage beyond the inlet rating. Environmental sensors are optional and sold separately.

Verify L6-20 receptacle and vertical clearance

Confirm the facility provides an L6-20R receptacle on a 16 A branch circuit matching 120 V AC or 230 V AC service. The 39.4 inch height requires sufficient vertical space in the 42U rack alongside other 0U equipment. Network management needs an Ethernet drop for the RJ-45 interface. Buyers needing more than 24 outlets or a higher current rating should consider additional or larger PDUs.

Fordele

  • 24 outlets in a 0U vertical form factor maximise rack density
  • 12 C13 and 12 C39 connectors support mixed IEC device loads
  • 16 A input at 120 V or 230 V delivers up to 3.8 kW
  • Embedded hot-swappable gigabit network module enables remote management and zero-trust security
  • Chain-of-trust encryption with secure firmware boot protects the PDU from network cyberattacks

Specifikationer

BrandEaton
ModelEVMAL620A
Part NumberEVMAL620A
TypePDUs & Line Conditioners
Rack Size0U
Input Voltage120 V AC
230 V AC
Maximum Input Current16 A
Cord Length10 ft. Cord
Output Connector(s)12 x IEC 60320 C13
12 x IEC 60320 C39
Forsendelsesvægt4.99 kg
Pakkestørrelse1176 × 198 × 140 mm

Spørgsmål om denne vare

Should I choose a PDU with C13 outlets or C39 outlets for my servers?

This unit provides twelve IEC 60320 C13 outlets and twelve IEC 60320 C39 outlets, so you can connect both standard server cords and higher-current devices without choosing between them.

What does the 3.8 kW power rating mean for my rack equipment?

At 16 A maximum input current, the PDU delivers up to 3.8 kW across twenty-four outlets, supporting dense 42U rack deployments at 120 V AC or 230 V AC.

How does the L6-20P plug limit what I can connect?

The NEMA L6-20P input plug requires a matching 20 A locking receptacle on your 120 V or 230 V supply, capping total draw at 16 A continuous per the unit rating.