Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.

Prisvagt Log ind

Tripp Lite

Tripp Lite PDUMH30HV PDU 5.8 kW 30A 208/240V 16 C13 2 C19 L6-30P 12ft 2U

SKU CH-AC4K-TPJJN MPN PDUMH30HV

A metered 2U rack PDU delivering 5.8 kW at 208/240 V with 16 C13 and 2 C19 outlets, dual 20 A breakers, and built-in current meters on a 12 ft L6-30P cord

  • TypeMetered
  • Rack Size2U
  • StyleRackmount
  • CertificationsTested to UL 60950-1 (USA), CSA (Canada), Class A (Emissions
  • ROHSYes
  • Package Includes2U rack PDU Mounting brackets Plug retention plates User man
  • Metered display shows real-time load per bank for balanced power management
  • 18 outlets (16 C13 and 2 C19) support dense rack equipment
  • Two 20 A breakers protect each 9-outlet bank from overloads
  • 12 ft attached cord with NEMA L6-30P plug simplifies installation
  • 2U horizontal form factor fits standard 19 in racks

Metered 2U rack PDU

The Tripp Lite PDUMH30HV is a metered power distribution unit that fits a standard 2U horizontal rack space. It accepts a single-phase 208 or 240 volt supply through a NEMA L6-30P plug on a 12 foot cord. The unit delivers power through eighteen locking IEC outlets, sixteen C13 and two C19, for dense server or network deployments.

Continuous load limit

Agency derating restricts continuous current to 24 amps on the 30 amp inlet, yielding a practical ceiling of 5.8 kilowatts at 240 volts. Two 20 amp branch breakers each protect a bank of nine outlets, so no single bank can exceed its breaker rating. The attached meters display real-time amperage per bank to help balance loads and avoid nuisance trips.

Eighteen mixed IEC outlets

Sixteen C13 and two C19 receptacles determine which equipment plugs in directly without adapters. Builders needing more C19 connections or a different inlet type will need another model.

Fordele

  • Metered display shows real-time load per bank for balanced power management
  • 18 outlets (16 C13 and 2 C19) support dense rack equipment
  • Two 20 A breakers protect each 9-outlet bank from overloads
  • 12 ft attached cord with NEMA L6-30P plug simplifies installation
  • 2U horizontal form factor fits standard 19 in racks

Specifikationer

BrandTripp Lite
ModelPDUMH30HV
TypeMetered
Rack Size2U
StyleRackmount
CertificationsTested to UL 60950-1 (USA), CSA (Canada), Class A (Emissions), NOM (Mexico), RoHS compliant, TAA Compliant
ROHSYes
Package Includes2U rack PDU
Mounting brackets
Plug retention plates
User manual
Input Voltage200 / 208 / 240V
Maximum Input Current30A
Input Connector(s)NEMA L6-30P
Cord Length12 Feet
Output Voltage200 / 208 / 240V
Output Frequency50/60Hz
Output Connector(s)16 x C13, 2 x C19
Overload ProtectionTwo 20A breakers protect 9 outlets each
Operating Environment-15 - 50 Celcius degree
Operating Relative Humidity5 - 95%
Operating Elevation0 - 10000 Feet
Features30A single phase 208 / 240V Metered Power Distribution Unit / PDU (Agency derated to 24A continuous)
Set of two lighted meters report PDU output current in amps for each 9 outlet load bank
Attached NEMA L6-30P 30A 208 / 240V input plug and 12Feet cord
2U horizontal rackmount format installs in two rack spaces
18 output receptacles (16 x C13, 2 x C19)
Outlets are arranged in two 9 outlet load banks, each with separate 20A breaker and current metering
Mounting flanges support installation in 2 and 4 post racks, with additional support for wall-mount and under-counter installation forma
Dimensions3.50" x 17.50" x 12.50"
Weight13.70 lbs.
Forsendelsesvægt6.90 kg
Pakkestørrelse511 × 437 × 203 mm

Spørgsmål om denne vare

Should I choose the PDU with 16 C13 and 2 C19 outlets or a different outlet mix?

This model provides exactly 16 IEC C13 outlets and 2 IEC C19 outlets across two load banks of nine outlets each.

What does the 5.8 kW rating mean once the unit is installed in my rack?

The 5.8 kW rating reflects the maximum apparent power at 208/240 V; the agency derating limits continuous draw to 24 A per the dual 20 A breakers.

How does the NEMA L6-30P input plug affect what I can actually draw?

The L6-30P plug connects to a 30 A 208/240 V circuit, but the two 20 A breakers cap each nine-outlet bank at 20 A.

Også på denne hylde

Kunderne har også sammenlignet disse

Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.