Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.

Prisvagt Log ind

Tripp Lite

Tripp Lite PDUV15 Basic PDU 0U 14x NEMA 5-15R 15ft

SKU CH-CW2P-JDGYH MPN PDUV15

Vertical 0U power strip distributes 120 V across fourteen NEMA 5-15R outlets from a 15 ft NEMA 5-15P cord with 15 A overload protection

  • TypeBasic
  • Rack Size0U
  • StyleVertical Rackmount, Wallmount, Raceway, Workbench
  • CertificationsTested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (
  • ROHSYes
  • Input Voltage100V; 120V; 127V
  • 14 outlets distribute power to multiple devices
  • 15 ft cord reaches distant rack locations
  • 0U vertical design preserves rack space for equipment
  • 15 A overload protection guards connected hardware
  • toolless mounting buttons simplify installation in compatible racks

14-outlet vertical PDU for dense racks

This 0U basic power distribution unit adds fourteen NEMA 5-15R receptacles to a 120 V single-phase circuit. It targets server rooms and network closets that need maximum outlet density without intelligence or switching. The switch-free design prevents accidental power loss to connected gear. It suits administrators who want simple, reliable distribution.

Button-mount vertical format saves rack units

Toolless mounting buttons let the unit snap into Tripp Lite and compatible button-mount racks, and the buttons can be relocated for rear-facing installation. Wall-mount and raceway options are also supported. Because it occupies zero rack units, it leaves every U free for servers, switches or storage. The fifteen-foot input cord with NEMA 5-15P plug reaches distant wall outlets or UPS systems.

15 A overload protection sustains continuous load

A built-in 15 A breaker protects the strip and downstream equipment during sustained draws up to 1.44 kW. The unit is tested to UL 60950-1 and CSA C22.2 No. 60950-1-03 and is RoHS compliant. It operates at 50 or 60 Hz across 100 V, 120 V and 127 V inputs. Buyers who need metered power, remote switching or environmental monitoring should look at managed PDUs instead.

Fordele

  • 14 outlets distribute power to multiple devices
  • 15 ft cord reaches distant rack locations
  • 0U vertical design preserves rack space for equipment
  • 15 A overload protection guards connected hardware
  • toolless mounting buttons simplify installation in compatible racks

Specifikationer

BrandTripp Lite
ModelPDUV15
TypeBasic
Rack Size0U
StyleVertical Rackmount, Wallmount, Raceway, Workbench
CertificationsTested to UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (Canada)
ROHSYes
Input Voltage100V; 120V; 127V
Maximum Input Current15A
Input Connector(s)NEMA 5-15P
Cord Length15.0 Feet
Output Voltage120V
Output Frequency50/60Hz
Output Watts (VA)1800 VA
Output Connector(s)14 x NEMA 5-15R
Overload Protection15A
FeaturesSwitch-free design prevents accidental shutoff
Toolless mounting buttons enable simple installation in Tripp Lite and other button-mount compatible equipment racks
Rear facing installation buttons can be relocated to the left or right surface of the PDU for rear, center or forward-facing outlet orientation in compatible racks
Included nut and bolt mounting brackets supports installation in non button-mount compatible racks
Mounting brackets also enable secure wallmount installation in a variety of raceway or workbench applications
Dimensions1.75" x 36" x 1.25"
Weight3.3 lbs.
Forsendelsesvægt1.75 kg
Pakkestørrelse1031 × 99 × 61 mm

Spørgsmål om denne vare

What is the maximum continuous load this PDU can handle before its overload protection trips?

The built-in 15 A breaker will trip if sustained draw exceeds 15 A at 120 V.

How much heat or noise does the PDU produce when running all day?

It has no fans or moving parts, so it generates minimal heat and operates silently.

What rack mounting system must I already have for the toolless buttons to work?

The toolless buttons fit Tripp Lite and other button-mount compatible equipment racks.