Vi tager imod kryptovaluta — så den krypto, du ejer, kan købe rigtig hardware.Betal med krypto, brug det på rigtig hardware. Gratis, forsikret levering til hele verden ved køb over 399 $. Neutrale, umærkede papkasser, sendt fra Tyskland.Gratis, forsikret levering over 399 $. Din kurs låses i 30 minutter, så snart kassen åbner.Kurs låst i 30 minutter. Hver vare er forseglet, har kontrolleret serienummer og er dækket af 24 måneders garanti.Forseglet, 24 måneders garanti.

Prisvagt Log ind

Tripp Lite

Tripp Lite SMART2200RMXLN 1950VA 1950W 120V UPS 7 Outlets 2U Rack/Tower

SKU CH-QH2H-74N0P MPN SMART2200RMXLN

Line-interactive sine-wave UPS delivers 1950 VA and 1950 W to seven NEMA outlets with automatic voltage regulation and a pre-installed network card

  • International Version120V
  • Input ConnectionNEMA 5-20P
  • VA Rating1950 VA
  • Watts1950 Wats
  • Output Voltage120V
  • Output Frequency50 / 60 Hz

VA 2200 VA w/ WEBCARDLX

De overstregede versioner findes, men er ikke på lager her.

  • 95 kVA and 1.95 kW capacity supports critical IT loads
  • Seven NEMA outlets including one L5-20R protect connected equipment
  • Sine-wave output with automatic voltage regulation corrects voltage fluctuations
  • Pre-installed network card enables remote management and monitoring
  • Four minutes runtime at full load extends operational continuity

1.95 kVA line-interactive UPS for IT deployments

The Tripp Lite SmartPro SMART2200RMXLN delivers 1950 VA and 1950 W of sine-wave battery backup at 120 V. Six NEMA 5-20R outlets and one NEMA L5-20R outlet connect servers, network gear or telecom equipment. A pre-installed network card enables remote monitoring from deployment day one.

Automatic voltage regulation corrects brownouts

AVR adjusts incoming power without draining the battery, preserving runtime for genuine outages. The sealed VRLA battery bank supplies four minutes at full 1950 W load or twelve minutes at half load of 975 W. Recharge completes in under eight hours, and the unit operates between 32 °F and 104 °F.

2U rack or tower mounting with multiple management

Included rails secure the 65.3 lb chassis in a standard rack; rubber feet support tower orientation on a shelf or floor. USB, DB9 serial, contact-closure, EPO and RJ45 interfaces allow scripted shutdowns and SNMP alerts. The front LCD reports load, voltage and battery status at a glance.

Fordele

  • 95 kVA and 1.95 kW capacity supports critical IT loads
  • Seven NEMA outlets including one L5-20R protect connected equipment
  • Sine-wave output with automatic voltage regulation corrects voltage fluctuations
  • Pre-installed network card enables remote management and monitoring
  • Four minutes runtime at full load extends operational continuity

Specifikationer

BrandTRIPP LITE
SeriesSmartPro
ModelSMART2200RMXLN
International Version120V
Input ConnectionNEMA 5-20P
VA Rating1950 VA
Watts1950 Wats
Output Voltage120V
Output Frequency50 / 60 Hz
Outlets7
Outlet Type(6) NEMA 5-20R; (1) NEMA L5-20R
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load (min.): 4 min. (1950W)
Half Load (min.): 12 min. (975W)
Battery Recharge Time<8 Hours
Interface PortContact closure; DB9 Serial; EPO (emergency power off); Micro-USB; Pre-installed network card; RJ45 Network; USB (HID enabled); USB-A; USB-B
RackmountableYes
TemperatureOperating Temperature Range: 32° to 104°F (0° to 40°C)
Storage Temperature Range: 5° to 122°F (-15° to 50°C)
Humidity20 to 95%, non-condensing
Dimensions3.40" x 17.20" x 23.74"
Weight65.3 lbs.
Package Contents1950VA 1950W 120V Line-Interactive UPS
WEBCARDLXE network management card
USB cable
DB9 cable
Rack-mounting hardware
Tower support stands
Safety instructions
Advanced User Guide
Forsendelsesvægt35.38 kg
Pakkestørrelse607 × 559 × 226 mm

Andre versioner af denne model

5 flere i samme serie

Samme familie, men med anden hukommelse, køler eller clockfrekvens — sammenlign, før du bestemmer dig.

Spørgsmål om denne vare

Should I choose the 1950 VA model or the 2200 VA version listed in the title?

The model SMART2200RMXLN is rated at 1950 VA and 1950 W; the 2200 VA figure in the supplier title refers to the same unit.

What does the 1950 W rating mean when the UPS is powering my rack equipment?

It can supply up to 1950 watts continuously; at full load the internal battery provides about 4 minutes of runtime, and at half load (975 W) about 12 minutes.

Which network management standard does the pre-installed card use, and what does it limit?

The card provides SNMP over RJ45 for remote monitoring and shutdown; it does not increase the 1950 W output capacity.

Også på denne hylde

Kunderne har også sammenlignet disse

Samme hylde, samme kasse — otte mønter og 30 minutters kurslås.