Me võtame vastu krüptoraha — nii saab teie hoitav krüptoraha osta päris riistvara.Makske krüptorahaga, kulutage seda päris riistvarale. Tasuta kindlustatud tarne kogu maailmas, üle 399 $. Lihtsad, kaubamärgita väliskarbid, saadetud Saksamaalt.Tasuta kindlustatud tarne üle 399 $. Teie kurss lukustatakse 30 minutiks kohe, kui kassa avaneb.Kurss lukustatud 30 minutiks. Iga toode on pitseeritud, selle seerianumber on kontrollitud ja sellel kehtib 24-kuuline garantii.Pitseeritud, 24-kuulise garantiiga.

Hinnavaatlus Logi sisse

Vertiv

Vertiv AS5C0NCWGNNXLKB 15 kVA UPS 5 min runtime

SKU CH-WVRD-2CVCS MPN AS5C0NCWGNNXLKB

A 15 kVA online double-conversion UPS with 5 minutes full-load runtime, scalable to N+1 redundancy in a rack or tower form factor

  • International Version208V
  • Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
  • Input Frequency40 Hz to 70 Hz auto-sensing
  • Input Connection4-Wire (L-L-N-G)
  • VA Rating15 kVA
  • Watts13.5 kW
  • 15 kVA scalable UPS protects critical loads
  • 5 minutes full-load runtime keeps systems running
  • 16 minutes half-load runtime extends outage coverage
  • Rack or tower form factor fits diverse spaces
  • LCD status display gives instant operational visibility

15 kVA split-phase UPS for critical loads

The Vertiv Liebert AS5C0NCWGNNXLKB is a new online double-conversion UPS rated at 15 kVA and 13.5 kW. It accepts 200/100, 208/120, 220/110, 230/115 or 240/120 VAC input through a four-wire connection and delivers the same split-phase voltages to connected equipment. The unit operates as a rack or tower module and includes a factory-installed SNMP webcard for network management.

Runtime limits at full and half load

At full load the internal valve-regulated lead-acid batteries provide 5 minutes of backup power, extending to 16 minutes when the load is reduced by half. The UPS auto-senses input frequency between 40 Hz and 70 Hz and defaults to 60 Hz output, with 50 Hz available through user configuration. Operating temperature range is 0 °C to 40 °C with humidity up to 95 per cent non-condensing.

Five-minute full-load runtime decides fit

The 5-minute full-load runtime is the single figure that determines whether this UPS covers the gap until generator start or orderly shutdown. Buyers who need a longer bridge at maximum load must look elsewhere. The module weighs 470 lbs and measures 27" x 17" x 32", requiring adequate floor or rack space and structural support.

Põhijooned

  • 15 kVA scalable UPS protects critical loads
  • 5 minutes full-load runtime keeps systems running
  • 16 minutes half-load runtime extends outage coverage
  • Rack or tower form factor fits diverse spaces
  • LCD status display gives instant operational visibility

Tehnilised andmed

BrandVertiv
SeriesLiebert
ModelAS5C0NCWGNNXLKB
International Version208V
Input Voltage Range200/100, 208/120, 220/110, 230/115, 240/120 VAC
Input Frequency40 Hz to 70 Hz auto-sensing
Input Connection4-Wire (L-L-N-G)
VA Rating15 kVA
Watts13.5 kW
Output Voltage200/100, 208/120, 220/110, 230/115, 240/120 VAC
Output Frequency60Hz default; 50/60Hz user-configurable
Battery TypeValve Regulated Lead Acid (VRLA)
Battery Run TimeFull Load: 5 mins.
Half Load: 16 mins.
TemperatureOperating temperature: 32°F - 104°F (0°C - 40°C)
Humidity0 - 95%, non-condensing
Dimensions27" x 17" x 32"
Weight470 lbs.
Tarnekaal256.28 kg
Pakendi mõõtmed813 × 813 × 432 mm

Selle mudeli teised versioonid

5 veel samast sarjast

Sama seeria, erinev mälumaht, jahutus või taktsagedus — võrrelge enne otsustamist.

Küsimused selle toote kohta

How do I choose between the 5-minute and 16-minute runtime figures for the AS5C0NCWGNNXLKB?

The 5-minute figure applies at the full 15 kVA load; the 16-minute figure applies when the load is roughly half that. Size the unit so your critical equipment stays under the half-load threshold if you need the longer window.

What does the 15 kVA rating mean for the actual power I can draw from this UPS?

The unit delivers up to 13.5 kW of real power at the 15 kVA apparent-power rating, so your connected load must not exceed 13.5 kW.

What does the 4-wire L-L-N-G input connection require in my electrical panel?

It needs two hot legs, a neutral and a ground, matching a 120/208 V split-phase service; the UPS auto-senses input frequency between 40 Hz and 70 Hz.