Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.
MINUTEMAN
A switched 0U vertical PDU with 24 NEMA 5-15/20R outlets, hardwired 20 A input, a local LCD and IP-addressable remote management over Ethernet
Model RPM2024N1LCD-HW
The MINUTEMAN RPM2024N1LCD-HW is a 0U vertical power distribution unit built for server rooms that need remote control over many outlets. It delivers 24 NEMA 5-15/20R receptacles fed by a 20 A hardwired input with a 10 ft cord. Network administrators can manage power state for each outlet individually through a single IP address.
The unit relies on convection airflow within the rack and adds no active fans, so it contributes no audible noise. An integrated LCD reports real-time amperage, IP address, temperature and humidity without requiring a separate console. Input circuit-breaker protection trips at 20 A to prevent overload damage.
Free monitoring software aggregates daily, weekly, monthly and yearly consumption logs for up to 5000 entries per log type. The embedded web server supports IPv4, IPv6, SNMP v1/v2c/v3, SSH, RADIUS and SSL for encrypted browser setup. Role-based accounts and IP filtering restrict configuration changes to authorised personnel.
| Brand | MINUTEMAN |
|---|---|
| Model | RPM2024N1LCD-HW |
| Type | Power Distribution Units |
| Style | 0U Vertical Installation |
| Certifications | 62368-1 Certification |
| Maximum Input Current | 20A |
| Input Connector(s) | Hardwire |
| Cord Length | 10 ft |
| Output Connector(s) | Front Panel Receptacles: (24) 5-15/20R |
| Maximum Output Current | 20A |
| Overload Protection | Input Circuit Breaker Protection |
| Features | IP-addressable Remote Power Manager Built-in Web Server to support Remote Power Management Event Notifications via Email or SNMP Traps Local LCD displays Amps, IP Address, Temperature and/or Humidity Daily, Weekly, Monthly & Yearly Power Consumption Data 10/100 Base-T Ethernet Port IPv4, IPv6 Support and SNMP Support (v1,v2c,v3) Telnet, SSH Encryption Support Radius Authentication User Account for Three Different Permissions Management Systems Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm SSL Web Browser for Set Up and Operation IP Address Filtering Maximum 5,000 E |
| Težina pošiljke | 6.80 kg |
| Dimenzije pakiranja | 1890 × 221 × 109 mm |
Druge verzije ovog modela
Ista obitelj, različita memorija, hladnjak ili frekvencija — usporedite prije kupnje.
Mount the unit vertically in a rack using the 0U brackets, then connect the 10 ft hardwire input to a 20 A branch circuit; the step often missed is configuring the IP address on the 10/100 Base-T Ethernet port before applying load.
The input circuit breaker provides overload protection and can be reset; no user-replaceable fuses or batteries are present, so ongoing maintenance is limited to firmware upgrades via the built-in web server and occasional LCD cleaning.
The 20 A input circuit breaker will trip once total draw exceeds 20 A, which is the first hard limit under sustained use across the 24 NEMA 5-15/20R receptacles.
Također u ovoj kategoriji
Ista polica, ista blagajna — osam valuta i blokada tečaja na 30 minuta.
Ono što šaljete, i ono u čemu gledate cijene.
Poslano iz Vašeg novčanika na blagajni
Samo prikaz — katalog je izražen u dolarima
Nijedna valuta ne odgovara.
Odaberite jezik na kojem Vam se stranica obraća.
Nema odgovarajućeg jezika.
Novi ste ovdje?
Već imate račun?
Ne postoji automatsko resetiranje: ova trgovina ne šalje e-poštu, stoga ne postoji jednokratna poveznica koju biste mogli zatražiti. Ostavite adresu uz svoj račun, netko će je ručno obraditi.
Zahtjev zaprimljen
Ništa neće stići u Vaš pretinac e-pošte — ova trgovina uopće ne šalje e-poštu. Netko će to ručno preuzeti.
Sjetili ste se?