Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.
MINUTEMAN
A switched 0U vertical PDU with 24 NEMA 5-15R outlets, 15 A IEC320 C20 input, 10 ft cord, local LCD metering and IP-addressable remote outlet control
Model RPM1524N1LCD
The MINUTEMAN RPM1524N1LCD is a 0U vertical power distribution unit that provides 24 NEMA 5-15R outlets from a single IEC320 C20 input. It is built for network administrators who need to control and monitor power to multiple rack-mounted devices from one IP address. The 10 ft cord allows flexible placement within the cabinet.
A 15 A input circuit breaker protects the strip from continuous overload rather than relying on short-term surge handling. The local LCD reports real-time amperage, temperature and humidity so operators can spot thermal trends before they trip the breaker. Email or SNMP traps deliver threshold alerts without requiring a constant browser session.
Verify that your rack power source terminates in an IEC320 C20 receptacle and that the 10 ft inlet reaches it without strain. Confirm the upstream circuit can supply 15 A continuously for the intended load. Ensure a 10/100 Base-T Ethernet drop is available for the management port and that your monitoring stack accepts SNMP v1, v2c or v3 traps.
| Brand | MINUTEMAN |
|---|---|
| Model | RPM1524N1LCD |
| Type | Power Distribution Units |
| Style | 0U Vertical Installation |
| Certifications | 62368-1 Certification |
| Maximum Input Current | 15A |
| Input Connector(s) | IEC320 C20 |
| Cord Length | 10 ft |
| Output Connector(s) | Front Panel Receptacles: (24) 5-15 R |
| Maximum Output Current | 15A |
| Overload Protection | Input Circuit Breaker Protection |
| Features | IP-addressable Remote Power Manager Built-in Web Server to support Remote Power Management Event Notifications via Email or SNMP Traps Local LCD displays Amps, IP Address, Temperature and/or Humidity Daily, Weekly, Monthly & Yearly Power Consumption Data 10/100 Base-T Ethernet Port IPv4, IPv6 Support and SNMP Support (v1,v2c,v3) Telnet, SSH Encryption Support Radius Authentication User Account for Three Different Permissions Management Systems Alarm Notification via Email, SNMP, Syslog, LED or Audible Alarm SSL Web Browser for Set Up and Operation IP Address Filtering Maximum 5,000 E |
| Težina pošiljke | 6.35 kg |
| Dimenzije pakiranja | 1890 × 221 × 109 mm |
Druge verzije ovog modela
Ista obitelj, različita memorija, hladnjak ili frekvencija — usporedite prije kupnje.
The unit draws up to 15 A through its IEC320 C20 inlet and passes power to 24 NEMA 5-15R outlets; it has no built-in fans, so it adds no audible noise and only the minimal heat from its internal circuitry.
A standard CAT5 Ethernet cable for the 10/100 Base-T port and a 10 ft IEC320 C20 power cord are required to reach the upstream UPS or wall circuit.
The RJ-45 port negotiates 10/100 Base-T speeds and supports IPv4, IPv6, SNMP v1/v2c/v3, SSH and Telnet, so it will communicate with legacy 10 Mbps switches without configuration changes.
Također u ovoj kategoriji
Ista polica, ista blagajna — osam valuta i blokada tečaja na 30 minuta.
Ono što šaljete, i ono u čemu gledate cijene.
Poslano iz Vašeg novčanika na blagajni
Samo prikaz — katalog je izražen u dolarima
Nijedna valuta ne odgovara.
Odaberite jezik na kojem Vam se stranica obraća.
Nema odgovarajućeg jezika.
Novi ste ovdje?
Već imate račun?
Ne postoji automatsko resetiranje: ova trgovina ne šalje e-poštu, stoga ne postoji jednokratna poveznica koju biste mogli zatražiti. Ostavite adresu uz svoj račun, netko će je ručno obraditi.
Zahtjev zaprimljen
Ništa neće stići u Vaš pretinac e-pošte — ova trgovina uopće ne šalje e-poštu. Netko će to ručno preuzeti.
Sjetili ste se?