Prihvaćamo kriptovalute — tako kriptovalute koje posjedujete mogu kupiti pravi hardver.Plaćajte kriptovalutom, trošite je na pravi hardver. Besplatna osigurana dostava diljem svijeta iznad 399 $. Obični vanjski kartoni bez oznaka, otpremaju se iz Njemačke.Besplatna osigurana dostava iznad 399 $. Vaš je tečaj blokiran 30 minuta od otvaranja blagajne.Tečaj blokiran 30 minuta. Svaki je artikl zapečaćen, njegov serijski broj provjeren, i pokriven jamstvom od 24 mjeseca.Zapečaćen, jamstvo 24 mjeseca.

Praćeni artikli Prijava

Vertiv

Vertiv Liebert AL3C0NHWGNNXLKB 15 kVA 13.5 kW 208 V UPS

SKU CH-3PF8-2W053 MPN AL3C0NHWGNNXLKB

A 15 kVA online double-conversion UPS with lithium-ion batteries delivering 13.5 kW at 208/120 VAC and eight minutes runtime at full load

  • International Version208V
  • Input Voltage Range200/208/220/230/240 VAC
  • Input Frequency40 Hz to 70 Hz auto-sensing
  • Input Connection3-Wire (L-L-G)
  • VA Rating15 kVA
  • Watts13.5kW
  • Continuous power with double-conversion online topology
  • 15 kVA and 13.5 kW capacity supports critical loads
  • Lithium-ion battery delivers 8 minutes at full load
  • Hot-swappable modules enable maintenance without interruption
  • Wide 200–240 VAC input range handles voltage variation

15 kVA 208 V Three-Phase UPS

The Vertiv Liebert AL3C0NHWGNNXLKB is a double-conversion online UPS rated at 15 kVA and 13.5 kW. It accepts 200 to 240 VAC three-wire input and delivers 208/120 VAC output. Lithium-ion batteries provide 8 minutes runtime at full load or 17 minutes at half load. The unit operates from 0 to 40 °C in 0 to 95 % non-condensing humidity.

Hot-Swappable Modules Replace Fixed Units

Power, battery and control modules can be exchanged without shutting down the connected load. This design suits sites that cannot schedule maintenance windows, such as data centres, medical facilities or industrial processes. The jump is worth it when uninterrupted uptime outweighs the cost of a traditional fixed-module UPS.

Verify 3-Wire 208 V Service and Floor Capacity

Confirm the site provides 3-wire L-L-G service within the 200 to 240 VAC range and that the electrical panel can supply the required current. The cabinet measures 42 by 17 by 32 inches and weighs 633 lbs, so ensure the floor or rack can support the weight and that clearance allows module removal.

Istaknuto

  • Continuous power with double-conversion online topology
  • 15 kVA and 13.5 kW capacity supports critical loads
  • Lithium-ion battery delivers 8 minutes at full load
  • Hot-swappable modules enable maintenance without interruption
  • Wide 200–240 VAC input range handles voltage variation

Specifikacije

BrandVertiv
SeriesLiebert
ModelAL3C0NHWGNNXLKB
International Version208V
Input Voltage Range200/208/220/230/240 VAC
Input Frequency40 Hz to 70 Hz auto-sensing
Input Connection3-Wire (L-L-G)
VA Rating15 kVA
Watts13.5kW
Output Frequency60Hz default; 50/60Hz user-configurable
Battery TypeLithium Ion
Battery Run TimeFull Load: 8 mins.
Half Load: 17 mins.
TemperatureOperating temperature: 32°F - 104°F (0°C - 40°C)
Humidity0 - 95%, non-condensing
Dimensions42" x 17" x 32"
Weight633 lbs.
Težina pošiljke287.12 kg
Dimenzije pakiranja1067 × 1067 × 432 mm

Druge verzije ovog modela

još 5 u istoj seriji

Ista obitelj, različita memorija, hladnjak ili frekvencija — usporedite prije kupnje.

Pitanja o ovom artiklu

What clearance does the 42" x 17" x 32" rack/tower cabinet need for front and rear airflow?

The unit is 42 inches tall, 17 inches wide and 32 inches deep; allow at least 24 inches in front for hot-swappable module removal and 12 inches at the rear for cable bend radius and ventilation.

How are the hot-swappable power, battery and control modules installed without shutting down the load?

Each module slides into the front of the chassis on guided rails and locks with a captive thumbscrew; the double-conversion topology keeps the inverter online while you replace a module one at a time.

When will the lithium-ion battery packs need replacement and what is the procedure?

At 32°F–104°F ambient the packs typically last 8–10 years; when runtime drops below 8 minutes at full load, open the front door, release the module latch and slide in a new battery module while the UPS stays online.

Također u ovoj kategoriji

Kupci su usporedili ovo

Ista polica, ista blagajna — osam valuta i blokada tečaja na 30 minuta.