ASUS Vivo AiO V241EA-DB003 all-in-one PC 23.8" Intel Pentium Gold 7505 8GB DDR4 512GB
- Windows 10 Home 🙋♀…
- Intel Pentium Gold…
Við tökum við rafmynt — svo myntirnar sem þú átt geta keypt alvöru vélbúnað.Greiddu í rafmynt, eyddu henni í alvöru vélbúnað. Frí, tryggð sending um allan heim fyrir pantanir yfir 399 $. Hlutlausir pappakassar án merkinga, sendir frá Þýskalandi.Frí, tryggð sending yfir 399 $. Gengið þitt er læst í 30 mínútur um leið og greiðsluferlið hefst.Gengið læst í 30 mínútur. Hver vara er innsigluð, raðnúmer hennar yfirfarið, og hún nýtur 24 mánaða ábyrgðar.Innsiglað, með 24 mánaða ábyrgð.
DELL
1U rack server holds four 3.5" SATA drives and runs a 12-core Xeon Silver 4510 at 2.4 GHz with 24 threads and 30 MB cache
The Dell PowerEdge R660xs is a 1U rack server configured with one Intel Xeon Silver 4510 processor running at 2.4 GHz with 12 cores and 24 threads. It targets environments that need compute density without a second CPU, such as web hosting, virtualisation clusters or departmental databases. Buyers who require dual-socket scale or more than four drive bays should look elsewhere.
A dedicated heatsink handles the 150 W TDP of the single Xeon Silver 4510, while Dell Active Power Controller adjusts power draw to match workload demand. The 1U chassis uses high-speed fans that ramp with inlet temperature, so acoustic output rises under sustained load. Typical operation stays within the thermal envelope defined for the 150 W CPU limit.
The 3.5-inch chassis holds up to four SATA hard drives and uses embedded SATA without a hardware RAID controller, so data protection relies on software RAID or external solutions. Memory runs at 5600 MT/s using DDR5 RDIMMs, and the system boots in UEFI mode with GPT partitioning. Single-CPU layout leaves the second socket empty, limiting future expansion to storage only.
| Brand | DELL |
|---|---|
| Model | QUO-25458444-F6W4Z1 |
| Part Number | QUO-25458444-F6W4Z1 |
| Sendingarþyngd | 13.61 kg |
| Stærð sendingar | 762 × 508 × 508 mm |
Align the processor with the socket keying, lower the load plate, then torque the heatsink screws in a diagonal pattern to 11 in-lb; the step most often missed is the diagonal torque sequence.
Plan to replace SATA drives after five years or when SMART alerts appear, and reseat DDR5 modules if correctable ECC errors rise above the platform threshold.
The 150W heatsink reaches its thermal capacity before the power supply or memory bandwidth becomes a bottleneck.
Einnig í þessum vöruflokki
Sama hilla, sama greiðsluferli — átta myntir og 30 mínútna gengislæsing.
Það sem þú greiðir í, og það sem þú sérð verð í.
Sent úr veskinu þínu í greiðsluferlinu
Aðeins til skýringar — verð í vörulistanum eru í Bandaríkjadölum
Enginn gjaldmiðill passar við það.
Veldu tungumálið sem síðan talar við þig á.
Ekkert tungumál fannst.
Fyrsta heimsókn?
Áttu þegar aðgang?
Það er engin sjálfvirk endurstilling: þessi verslun sendir engan tölvupóst, svo það er enginn einnota tengill til að biðja um. Skildu netfangið eftir á aðganginum og einhver sinnir því handvirkt.
Beiðni skráð
Ekkert er á leiðinni í pósthólfið þitt — þessi verslun sendir engan tölvupóst. Einhver sinnir þessu handvirkt.
Mundir þú það?