ASUS Vivo AiO V241EA-DB003 all-in-one PC 23.8" Intel Pentium Gold 7505 8GB DDR4 512GB
- Windows 10 Home 🙋♀…
- Intel Pentium Gold…
Wij accepteren cryptovaluta — zo kunnen de munten die u bezit echte hardware kopen.Betaal in crypto, besteed het aan echte hardware. Gratis verzekerde verzending wereldwijd vanaf $399. Neutrale dozen zonder merk, verzonden vanuit Duitsland.Gratis verzekerde verzending vanaf $399. Uw koers wordt 30 minuten vastgezet zodra het afrekenen begint.Koers 30 minuten vastgezet. Elk artikel is verzegeld, het serienummer wordt gecontroleerd, en het valt onder 24 maanden garantie.Verzegeld, 24 maanden garantie.
DELL
1U rack server holds four 3.5" SATA drives and runs a 12-core Xeon Silver 4510 at 2.4 GHz with 24 threads and 30 MB cache
The Dell PowerEdge R660xs is a 1U rack server configured with one Intel Xeon Silver 4510 processor running at 2.4 GHz with 12 cores and 24 threads. It targets environments that need compute density without a second CPU, such as web hosting, virtualisation clusters or departmental databases. Buyers who require dual-socket scale or more than four drive bays should look elsewhere.
A dedicated heatsink handles the 150 W TDP of the single Xeon Silver 4510, while Dell Active Power Controller adjusts power draw to match workload demand. The 1U chassis uses high-speed fans that ramp with inlet temperature, so acoustic output rises under sustained load. Typical operation stays within the thermal envelope defined for the 150 W CPU limit.
The 3.5-inch chassis holds up to four SATA hard drives and uses embedded SATA without a hardware RAID controller, so data protection relies on software RAID or external solutions. Memory runs at 5600 MT/s using DDR5 RDIMMs, and the system boots in UEFI mode with GPT partitioning. Single-CPU layout leaves the second socket empty, limiting future expansion to storage only.
| Brand | DELL |
|---|---|
| Model | QUO-25458444-F6W4Z1 |
| Part Number | QUO-25458444-F6W4Z1 |
| Verzendgewicht | 13.61 kg |
| Pakketafmetingen | 762 × 508 × 508 mm |
Align the processor with the socket keying, lower the load plate, then torque the heatsink screws in a diagonal pattern to 11 in-lb; the step most often missed is the diagonal torque sequence.
Plan to replace SATA drives after five years or when SMART alerts appear, and reseat DDR5 modules if correctable ECC errors rise above the platform threshold.
The 150W heatsink reaches its thermal capacity before the power supply or memory bandwidth becomes a bottleneck.
Ook in deze afdeling
Dezelfde afdeling, dezelfde kassa — acht munten en een koers die 30 minuten vaststaat.
Waarmee u betaalt, en waarin u de prijzen leest.
Verzonden vanuit uw wallet bij het afrekenen
Alleen ter weergave — de catalogus is geprijsd in USD
Geen valuta gevonden.
Kies de taal waarin de site met u spreekt.
Geen taal gevonden.
Nieuw hier?
Al een account?
Er is geen automatisch herstel: deze winkel verstuurt geen e-mail, dus er is geen eenmalige link om aan te vragen. Laat het adres op het account achter en het wordt handmatig opgepakt.
Verzoek genoteerd
Er is niets onderweg naar uw inbox — deze winkel verstuurt helemaal geen e-mail. Iemand pakt dit handmatig op.
Weet u het weer?